What the takeoff said: Read from 000-Copy of 2498 A set 2025-0530 Revision 1.pdf, page 27 (text layer glyph-shifted +29, read from 150-200 dpi renders). Sections 2-6 and axonometric 1. Drawn: ceiling hanger wires and existing roof structure/ductwork/piping above an 11'-6" sales-area ceiling (grey/red/blue MEP by others), an 'Ext Ceiling Display' wood-slat feature at the entry (section 5), green dash-dot linear light lines along the top of millwork at 8'-2" and the soffit line (LAL/LAF strips, counted on E sheets), 1 EXIT sign (section 5, counted on E sheets), EQ-35 'MANGO' letters over the cash wall (section 3), EQ-33 'Click & Collect' panel and EQ-34 'Committed' round graphic on the cash wall, EQ-38b 'MANGO' sign at the entry (section 5, MC-16). No track, no unistrut/strut, no threaded rod or display-wire supports, no receptacle/J-box/data symbols, no dimensions for any electrical item, no responsibility matrix, no equipment schedule with electrical data, no demolition. No line is written: nothing electrical on this sheet has a count or measurement that the E sheets do not already carry. No marks file because nothing was counted here.