Door-schedule table (door numbers, hardware columns, keyed notes 1-12/6A/6B/7-7C) is drawn as vector text but does not surface in PyMuPDF's word-level text extraction for this page at all; keyword searches ('keypad','electromagnetic','allegion') only match unrelated words at y-coordinates greater than the page's own 1728pt height, indicating a CropBox/MediaBox offset defect on this page (the same class of defect already logged against A-150 in this run). All marks below were therefore read visually off 200-500dpi renders/crops of the schedule table and notes block and their coordinates are ESTIMATED from row order and proportional position in the rendered image, not machine-extracted from the text layer -- flagged low-precision positions, good for row identification, not for sub-row pixel accuracy.
Names come from: no legend on this sheet, so NECA 100-2006 is what a name rests on. It is the baseline for what a symbol MEANS, never for matching shapes — proportions differ per firm. Confirming a name here is a correction, and corrections are what build the firm's file.
Scale is UNSET. Nothing on this sheet has been measured. The reader declined to infer a scale rather than guess one, so there is no raceway and no branch wire off this sheet — together the largest block of material on a job of this kind. Set it from the title block and measurement becomes available.
Put your name in to mark this sheet up. Looking needs no name.
zoom100%sheetcounts6 of 6 marks drawn
Page 39 of 000-Copy of 2498 A set 2025-0530 Revision 1.pdf, recorded by the read.
Fetching page 39…
0 changes on this sheet, each saved as it was made · not saved as reviewed yet
Price from RRE Components8 on this sheet
Pick the RRE item for each count. The Draft Estimate opens when every sheet is answered. Put your name in above to answer these.
Circuit breaker (terminations counted) — POWER & DATA CONNECTION - POS STATION AT CASH COUNTER
No RRE Components assembly is a close match. Search the catalogue for one.
Nothing to highlight: not marked on the drawing. Counted from this sheet’s labels or schedule.
Recommended: not in this bid — The terminations line on this takeoff already counts these circuits, and RRE’s last retail job bought no breakers for circuits in its existing panels. Recommended: Not in this bid. Where the EC furnishes new breakers, search for the breaker. One answer here prices every line in this question.
Also answers 4 lines of this kind on other sheets: BREAKER - 1-POLE, IN NEW PANEL · BREAKER - NEW CIRCUITS IN EXISTING PANEL MD · BREAKER - NEW CIRCUITS IN EXISTING PANEL A · BREAKER - NEW CIRCUITS IN EXISTING PANEL B
recommended
None of these right?
Unistrut — UNISTRUT TRACK-SUSPENSION SUPPORT SYSTEM (P1000 UNISTRUT W/ ELONGATED HOLES, EC FURNISH & INSTALL)
No RRE Components assembly is a close match. Search the catalogue for one.
Nothing to highlight: not marked on the drawing. Counted from this sheet’s labels or schedule.
Recommended — RRE’s last retail job bought its unistrut by the foot (1,262.6 ft), RRE’s own item at 0.09 hr/ft.
1-5/8" P1000 UNISTRUT (per ft)recommendedRRE-UNISTRUT-FT · $4.51 material · 0.09 hr each
None of these right?
Linear / strip light (counted in pieces) — LIGHT FIXTURE TYPE MI-1 (schedule MIRROR W/LED)
No RRE Components assembly is a close match. Search the catalogue for one.
Nothing to highlight: not marked on the drawing. Counted from this sheet’s labels or schedule.
Recommended — This line counts 1 ea, not feet, so the per-foot item would price one foot a fixture. Recommended: INSTALL FIXTURE (install only, 0.33 hr each, fixture by quote). Where the drawing gives the run lengths, edit the quantity to the total feet and use LED LINEAR / STRIP (0.15 hr a foot) instead. One answer here prices every line in this question.
Also answers 1 line of this kind on other sheets: LIGHT FIXTURE TYPE 26-50.21 LED STRIP (base run, Oak Wall Panel/Repisa)
INSTALL FIXTURE (install only, fixture by quote)recommendedRRE-INSTALL-STRIP · $0.00 material · 0.33 hr each
None of these right?
LED driver / remote transformer — LED DRIVER / REMOTE TRANSFORMER FOR LIGHT FIXTURE TYPE MI-1
No RRE Components assembly is a close match. Search the catalogue for one.
Nothing to highlight: not marked on the drawing. Counted from this sheet’s labels or schedule.
Recommended: not in this bid — RRE’s last retail job carried no separate item for strip-light transformers: they rode in the strip install. Price it with the strip, or search for a driver if the job furnishes one separately. One answer here prices every line in this question.
Also answers 3 lines of this kind on other sheets: LED DRIVER/TRANSFORMER POWER CONNECTION & ACCESS COORDINATION · TRANSFORMER, CONCEALED IN ACCESS PANEL (DIV 26 KEYED NOTE 26-50.23) · LED REMOTE TRANSFORMER (millwork cabinet, back-of-cash-counter, note 26-50.23)
recommended
None of these right?
Double duplex receptacle — POWER RECEPTACLE - IT RACK (BACK OF HOUSE)
No RRE Components assembly is a close match. Search the catalogue for one.
Nothing to highlight: not marked on the drawing. Counted from this sheet’s labels or schedule.
Recommended — RRE’s last retail job: 6 double duplexes, bought as 20A standard duplexes with 2-gang plates in 4/S boxes. Recommended: DOUBLE 20 AMP DUPLEX STD.
DOUBLE 20 AMP DUPLEX STDrecommendedRRE Components 16014 · $14.67 material · 0.70 hr each
None of these right?
Occupancy / vacancy sensor — LOW VOLTAGE CABLING - ENTRY SECURITY/EAS SYSTEM
No RRE Components assembly is a close match. Search the catalogue for one.
Nothing to highlight: not marked on the drawing. Counted from this sheet’s labels or schedule.
Recommended — RRE’s last retail job: 11 × POWER PACK 120/277V-24V for the sensors (0.4 hr each), alongside 17 lighting-control installs. Recommended: P - POWER PACK. A wireless (Vive) sensor may need no power pack -- check the controls sheet.
P - POWER PACKrecommendedRRE Components 31566 · $3.88 material · 0.72 hr each
None of these right?
Controls wiring — LOW VOLTAGE CABLING - BURGLAR ALARM (6/18AWG)
No RRE Components assembly is a close match. Search the catalogue for one.
Nothing to highlight: not marked on the drawing. Counted from this sheet’s labels or schedule.
Recommended — No RRE Components item is built for control wiring; RRE carries work like this as labor hours (1 HOUR LABOR (CONTROLS), 1 hr each). Recommended: one hour for each counted -- change the quantity to the hours it takes.
1 HOUR LABOR (CONTROLS)recommendedRRE Components 31518 · $0.00 material · 1.00 hr each
None of these right?
Receptacle — POWER & LOW VOLTAGE - BURGLAR ALARM SOUNDER/VIDEO RECORDER
No RRE Components assembly is a close match. Search the catalogue for one.
Nothing to highlight: not marked on the drawing. Counted from this sheet’s labels or schedule.
Recommended — RRE’s last retail job: 25 × DUPLEX 20A RECP, STANDARD at 0.2 hr, in 4/S boxes with 1-gang plates -- commercial, not Romex. RRE’s last restaurant job: 20A duplex at 0.565 hr each. Recommended: DUPLEX 20 AMP STD.
DUPLEX 20 AMP STDrecommendedRRE Components 16013 · $10.61 material · 0.49 hr each
None of these right?
Lines RRE adds for this sheet2 to answer
RRE carries these on jobs like this one, and no symbol on the drawing counts them. Add each with a count, or answer “not in this bid”. The Draft Estimate opens when every one is answered. Put your name in above to answer these.
RRE PER-JOB KIT
The allowance RRE carries on every job: 20 5/8" anchors with all-thread, nuts and washers, sealant, five screw-cover boxes, channel cuts, pull tape and a $50 device allowance.
Recommended — RRE priced this on 4 of 5 past jobs (80%). RRE carried these items at identical quantities on each of its last three jobs -- a fixed allowance, not a count (11.5 hr, $582). Recommended: RRE-HOUSE-KIT, once per job.
276 tan wire nuts, 92 insulated pigtails, 184 anti-short bushings with their screws, a 4x8 plywood backboard and 1" PVC fittings.
Recommended — RRE priced this on 4 of 5 past jobs (80%). RRE carried these at exactly these quantities on its two larger jobs (22.0 hr, $150), and about an eighth of them, with no backboard, on its smallest. Recommended: RRE-HOUSE-KIT-LOOSE on a job of restaurant or larger-retail size; leave it off a small fit-out.
eaRRE-HOUSE-KIT-LOOSE · RRE PER-JOB LOOSE PARTS (wire nuts, pigtails, bushings, backboard, PVC fittings) · 21.96 hr each
By symbol3 of 3 shown
6
all marks
hover a group to filter the plan
Counted here, not marked on the drawing
The takeoff counted these from this sheet (circuit labels, the panel schedule) without placing a mark. Marks for drawn symbols come with the symbol-counting step.