What the takeoff said: Read from 000-Copy of 2024.11.28_INT_US_CA_Roseville_Galleria at Roseville_LL PERMIT BID SET_FULL.pdf, page 29 (text layer + render). Details 1 Reference Storefront Section (1"=1'), ST-1 / ST-2 Storefront Detail and Section (3"=1'), plus Landlord Review Comments (same list as A301). Electrical content: 'NEW ILLUMINATED INTIMISSIMI LED SIGN L400' on the storefront structure - no J-box, conduit, power entry or support drawn; its power is the E3.0 keyed note 16 sign J-box on TC (L-1), already taken on E3.0 and not re-taken here. The triage 'furnished-by/installed-by' hits are 'NEW FLOOR SUPPLIED BY OWNER AND INSTALLED BY GC' and trim profiles 'BY GC' - no electrical scope. The 'EL PARAVENT' horizontal folding panel door is drawn with a track and floor socket only - no motor, operator or power shown. The fire alarm hit is the LL comment 'TENANT GC TO REINSTALL FIRE STROBE ON NEUTRAL PIER WHERE OCCURS', already carried as a coverage gap from A301. No responsibility matrix, no equipment schedule, no unistrut/rod/strut or display support, no LV positions, no demolition. No lines taken; no marks file written.