What the takeoff said: Read from 000-Copy of 2024.11.28_INT_US_CA_Roseville_Galleria at Roseville_LL PERMIT BID SET_FULL.pdf, page 30 (text layer + render). Details 1 Reference Storefront Section (1"=1'), ST-3 / ST-4 Storefront Detail and Section (3"=1'), plus Landlord Review Comments (same list as A301/A302). Electrical content: ST-3 draws 'NEW STOREFRONT TRACKLIGHT' in a 'CEILING RECESSED TRACK' in the bulkhead cove with 'GC TO PROVIDE TRACK BLOCKING AS REQUIRED' - wood blocking by GC, no unistrut, rod or clamp drawn; track and heads are counted on the E lighting plan and not re-taken. ST-4 draws one duplex outlet inside the storefront platform: 'NEW DUPLEX POWER SOCKET TO BE INSTALLED INSIDE PLATFORM. GC TO SUPPLY AND INSTALL NEW CABLE FLAP ON TOP OF FOOTBOARD' - this is the E3.0 keyed note 4 platform receptacle (L-13 via TC), already taken on E3.0 and not re-taken. The triage 'furnished-by/installed-by' hits are MDF panels, blocking, trim profiles and cable flaps 'BY GC' - no electrical scope. The fire alarm hit is the LL comment 'TENANT GC TO REINSTALL FIRE STROBE ON NEUTRAL PIER WHERE OCCURS', already carried as a coverage gap from A301. No responsibility matrix, no equipment schedule, no strut/display support, no LV positions, no demolition. No lines taken; no marks file written.