What the symbol names rest on. The set’s own legend (000-Copy-of-2498-A-set-2025-0530-Revision-1-p1, E-100, E-200), which is authoritative for this project.
The RRE item carries no price for the part named, so the estimate has the install labor and rough-in only, and the vendor or sub prices the rest. Send the lighting and gear lists from Material list & vendor quotes.
| Line | Needs a price for | Count | Sheet |
|---|---|---|---|
LIGHT FIXTURE TYPE LAL (schedule LAL) - LED strip / millwork linear, remote driver LIGHT FIXTURE TYPE LAL (schedule LAL) - LED strip / millwork linear, remote driver | LED REMOTE DRIVER | 153.8 ft | E-300 |
LIGHT FIXTURE TYPE LAF (schedule LAF) - LED strip / millwork linear, remote driver LIGHT FIXTURE TYPE LAF (schedule LAF) - LED strip / millwork linear, remote driver | LED REMOTE DRIVER | 125.3 ft | E-300 |
LIGHT FIXTURE TYPE P15.1W (schedule P15.1w) - track head LIGHT FIXTURE TYPE P15.1W (schedule P15.1w) - track head | LED TRACK SPOT FIXTURE | 115 ea | E-300 |
LIGHT FIXTURE TYPE P08.1W (schedule P08.1w) - track head LIGHT FIXTURE TYPE P08.1W (schedule P08.1w) - track head | LED TRACK SPOT FIXTURE | 95 ea | E-300 |
EMERGENCY BATTERY PACK, 90-MIN, FIELD-INSTALLED IN FIXTURE (tag /EMB, lighting note 6) EMERGENCY BATTERY PACK, 90-MIN, FIELD-INSTALLED IN FIXTURE (tag /EMB, lighting note 6) | LED EMERGENCYLIGHT DUAL | 18 ea | E-300 |
EXIT SIGN / EMERGENCY LIGHT, LED, 120V, 90-MIN BATTERY, TYPE EM2/EM3 PER A-004 (Rev 1 additional positions beyond E-300) Exit / emergency units drawn on A-004 Rev 1 egress plan in excess of the 7 exit signs counted on E-300: 13 EM2 + 4 EM3 = 17 drawn, less 7 on E-300 = 10. Furnish & install per E-200 EM schedule; unswitched on emergency circuit A-41. | LED GRN EXIT FIXTURE | 10 ea | A-004 |
EXIT SIGN, LED, 120V, 90-MIN BATTERY (schedule EX01/EX02, E-200 EM2/EM4) EXIT SIGN, LED, 120V, 90-MIN BATTERY (schedule EX01/EX02, E-200 EM2/EM4) | LED GRN EXIT FIXTURE | 7 ea | E-300 |
LIGHT FIXTURE TYPE BA/EM (schedule BA/EM) 4' suspended LED linear, 120V, with 90-min emergency battery, Bartco BSS210-...-WH+ED, back of house | LED EMERGENCYLIGHT DUAL | 3 ea | A-130 |
LIGHT FIXTURE TYPE QA/EM (schedule QA/EM) Recessed LED 2x2 flat panel, 120V, 31W, with 90-min emergency battery backup, C-Light C-TR-C-FP22-37L-35K-Wh | LED EMERGENCYLIGHT DUAL | 1 ea | A-130 |
Read off the schedules and notes. RRE buys none of the material named here. Check each against the responsibility matrix on the proposal: these are what it should say is by others.
| Line | Furnished by | Installed by | RRE’s part | Sheet |
|---|---|---|---|---|
1" CONDUIT STUB, LOW VOLTAGE DATA AT CASH WRAP The drawings say “by gc”. | GC | not stated | RRE installs / connects only | E-400 |
LIGHT FIXTURE TYPE S02 (schedule S02) The drawings say “owner furnished”. | Owner | not stated | RRE installs / connects only | A-130 |
LOW VOLTAGE BACKBOX, 4-SQ WITH SINGLE-GANG MUD RING AND 3/4" EMT STUB, TRACK-MOUNT SPEAKER (ST) CONNECTION POINT The drawings say “by gc.”. | GC | not stated | RRE installs / connects only | A-150 |
LUTRON VIVE POWPAK PHASE-SELECT MODULE RMJS-PNE-DV, INSTALL ONLY (vendor-furnished), ON 4-SQ J-BOX The drawings say “vendor-furnished”. | Vendor | not stated | RRE installs / connects only | E-900 |
LOW VOLTAGE BACKBOX, 4-SQ 2-1/8" DEEP WITH SINGLE-GANG MUD RING AND 3/4" EMT STUB TO ACCESSIBLE CEILING, WIFI ACCESS POINT (CEILING) The drawings say “by gc.”. | GC | not stated | RRE installs / connects only | A-150 |
LOW VOLTAGE BACKBOX, 4-SQ WITH SINGLE-GANG MUD RING AND 3/4" EMT STUB, CCTV CAMERA (CEILING) The drawings say “by gc”. | GC | not stated | RRE installs / connects only |
9 lines the reader wrote at zero are not listed: they add nothing to the bid.
Nothing in this tab.
Everything taken out of the bid, on any screen. Read why each was in the takeoff and why it is out, then confirm it belongs out — or change your mind: put it back (asked again on its sheet), or add it as labor hours only. The takeoff is signed off once every item is confirmed.
| Item | Why it was in the takeoff | Why it is out | Sheet | Taken out by | |
|---|---|---|---|---|---|
| EXISTING DUCT SMOKE DETECTOR RECONNECTION TO NEW AHU (UNIT SHUTDOWN INTERLOCK), EXISTING DETECTOR TO REMAIN — Reconnect existing duct-mounted smoke detector to shut down new AHU-1 / AHU-2 (one per unit); detector existing to remain; responsibility unassigned | Counted 2 'SD' hexagon symbols on M-300 Rev 1 cloud, one on each AHU duct (AHU-1 at x~1145, AHU-2 at x~1254, y~1292), leader note 'EXISTING DUCT MOUNTED SMOKE DETECTOR TO REMAIN. (TYP 2)'. Detectors are existing; the new AHUs need the shutdown interlock remade. No sheet read assigns this wiring - flagged for the estimator. (Model line id L-0108.) The model also raised 'responsibility unconfirmed - may be mall fire-alarm vendor', 'existing device, reconnect only', which the contract has no flag for; recorded here rather than dropped. | answered on the drawing instead of a RRE Components item. | M-300 | kelchlin · Sep 29, 6:27 PM | |
| TRACK, LINE-VOLTAGE 120V SINGLE-CIRCUIT, SURFACE/SUSPENDED (tracks 1-7) — TRACK, LINE-VOLTAGE 120V SINGLE-CIRCUIT, SURFACE/SUSPENDED (tracks 1-7) | Measured 29 drawn track runs (tracks 1-7, each parallel run of a grid on its own) at 3/16"=1'-0" (13.5 pt/ft) off the E-300 page image; no dimension strings on this sheet. Track 2's diagonal hatched grid in the triangle is taken as 6 runs of about 24 ft - confirm against the architect RCP. Heads are their own lines. Circuits A-23..33 via panel CL. (Model line id L-0039.) The model also raised 'measured from image, confirm', which the contract has no flag for; recorded here rather than dropped. | answered on the drawing instead of a RRE Components item. | E-300 | kelchlin · Sep 29, 6:20 PM | |
| JUNCTION BOX 4" SQ, 120V FEED TO REMOTE LED TRANSFORMER IN MILLWORK — Line-voltage J-box / connection point for the 26-50.23 remote transformer inside the back-cash cabinet (fed from the LAL/LAF lighting circuit on E-300). Includes the whip into the cabinet. | One remote transformer drawn in section 4 needs one 120V connection point. The detail draws no box or conduit; one J-box per transformer taken. The circuit comes from E-300 (LAL/LAF circuiting). (Model line id L-0103.) The model also raised 'hand_read', 'inferred', 'check E-300/E-400 for a J-box already carried at the cash wall', which the contract has no flag for; recorded here rather than dropped. | answered on the drawing instead of a RRE Components item. | A-410 | kelchlin · Sep 29, 6:17 PM | |
| LED REMOTE TRANSFORMER / DRIVER, CLASS 2, CONCEALED IN MILLWORK CABINET (spec 26-50.23) — Remote LED transformer for the 26-50.21 continuous LED strip at the back-of-cash wall (M-2A/M-2B) and the backlit MANGO logo above it; mounted concealed, accessible and vented inside the top of the back-cash cabinet (06-30.10). Install, mount and make line-voltage and Class 2 connections. | Section 4 (1 1/2"=1'-0") draws one 26-50.23 remote transformer box just under the cabinet top at 8'-2" top of millwork; detail 5 is an enlargement of the same spot (same transformer, not re-counted). Spec 26-50.23: 'LED transformer installed remotely concealed; to be accessible and well vented'. 26-50.21 note c: 'Transformer to be installed in an accessible cabinet or closet.' E-300 lighting note 7 points the LAL/LAF remote drivers to a millwork lighting plan; no E sheet counts the driver itself, so it is taken here. Only one transformer is drawn for the cash wall; the other LAL/LAF runs on E-300 will need their own drivers (gap). (Model line id L-0102.) The model also raised 'hand_read', 'furnish: with LED strip (fixture package) -- EC installs', 'possible overlap with LAL/LAF fixture line if the fixture assembly includes its driver', which the contract has no flag for; recorded here rather than dropped. | answered on the drawing instead of a RRE Components item. | A-410 | kelchlin · Sep 29, 6:17 PM | |
| TRANSFORMER / REMOTE LED DRIVER (spec 26-50.23), CONCEALED ABOVE DISPLAY CEILING IN TAPED-IN ACCESS PANEL - INSTALL & CONNECT, WITH 4" SQ J-BOX AND FLEX WHIP — Remote transformer drawn above the storefront display ceiling; note 26-50.23 'TRANSFORMER TO BE CONCEALED IN TAPED IN ACCESS PANEL'. Access panel itself by GC (drywall). | Counted the 26-50.23 transformer callout once in Section 3 (Existing Storefront Window Section, box drawn above the 11'-0" display ceiling) and once in Section 1 (Storefront Window Display Section, leader to the display ceiling line) = 2. The sections are typical cuts; the number of storefront bays that each need a transformer is not given here. Not on the E-sheet lines: E-300 LAL/LAF runs say 'remote driver, see millwork lighting plan (not in this set)' and carry no driver line; the only driver line is for S02 sconces. (Model line id L-0101.) The model also raised 'typical-section count, verify against storefront bays on A-200/A-130', 'sign transformer vs LED driver not stated (A-001 Mall Note 16 also requires concealed sign transformers)', 'A-090 matrix: LED/transformers Mango supply, G.C. install', which the contract has no flag for; recorded here rather than dropped. | answered on the drawing instead of a RRE Components item. | A-210 | kelchlin · Sep 29, 6:17 PM | |
| LED DRIVER / TRANSFORMER 75W 24VDC CLASS 2, REMOTE MOUNT (XLG-75 series) FOR S02 SCONCES, WITH J-BOX — Remote driver, (2) S02 sconces per driver per schedule note 7: 16 / 2 = 8 | Schedule note 7 on A-130: '(2) sconce lights per each transformer (XLG-75 series)'. 16 S02 / 2 = 8 drivers, each needing a 120V connection. Furnisher of the driver not stated (fixture vendor Owner). (Model line id L-0093.) The model also raised 'derived', 'furnish unclear', which the contract has no flag for; recorded here rather than dropped. | answered on the drawing instead of a RRE Components item. | A-130 | kelchlin · Sep 29, 6:17 PM | |
| LIGHT FIXTURE TYPE E06W (schedule E06w) — Recessed adjustable LED downlight 80mm, 110V, 18W, Flos 03.7630.B7.UL white, retail; owner furnished (vendor Owner), GC-furnished cone + rough-in plate per schedule note 5 | A-130 lighting schedule row E06w qty 28, location Retail, vendor Owner. E-300 has no E06W label (E-300 gap) so taken here from the schedule quantity; individual plan tags not marked (outlined lettering). (Model line id L-0091.) The model also raised 'schedule_qty', 'furnish: Owner (install only)', which the contract has no flag for; recorded here rather than dropped. | answered on the drawing instead of a RRE Components item. | A-130 | kelchlin · Sep 29, 6:17 PM |
Confirm each item, or Confirm all, to sign off.
Derived from what the read produced, so none of it can drift from the data behind it. A blocker stops a price being presented as complete; it never stops you looking. These definitions are this build’s own — no RRE document specifies them yet.
| Check | Status | What the check found |
|---|---|---|
| Sheet scale | blocker | Scale is UNSET on 4 of 8 plan sheet(s): A-004, A-092, A-130, A-150. Nothing on them has been measured, so there is no raceway and no branch wire — together the largest block of material on a job of this kind. Set the scale from each title block on the Drawings screen. |
| Sheets read for scope | warning | 27 sheet(s) were indexed but not read for scope: A-008, A-009, A-010, A-011, A-012, A-013, A-014, A-091, A-110, A-111, A-460, A-501, M-200, M-500, M-501, M-600, M-601, M-602, P-101, P-200, P-300, P-301, S100, FP-1, 007-rocklinelectric.net-Mail---Fwd_-Mango--...ion---Invitation-to-bid-DUE-05_08_2025-p1, 007-rocklinelectric.net-Mail---Fwd_-Mango--...ion---Invitation-to-bid-DUE-05_08_2025-p2, 007-rocklinelectric.net-Mail---Fwd_-Mango--...ion---Invitation-to-bid-DUE-05_08_2025-p3. Looked at by the takeoff and not read: no electrical work on it. Read them, or state the omission on the proposal — the basis of the offer already prints it. |
| Symbol source | pass | A symbol list was found on the drawings: 000-Copy-of-2498-A-set-2025-0530-Revision-1-p1 — COVER PAGE, E-100 — ELECTRICAL SPECIFICATIONS, E-200 — SYMBOLS LIST. The project legend is authoritative for this set and outranks everything else — NECA 100-2006 itself allows a drawing to use non-standard symbols provided the legend explains them. NECA 100-2006 stays underneath it for anything the legend leaves silent, and no conventions file exists for the engineering firm. |
| Symbols named | pass | All 641 marks belong to a named group. |
| Every line prices |
Edition: 2022 California Electrical Code, because in force for permits from 2023-01-01, as of the bid date 2025-05-08. City and county amendments are the AHJ’s: check them on any job inside a city that amends the code. “To check” means the code requires it and the drawings do not show it: send an RFI, or make the call. Nothing here is added to the bid on its own.
| Section | Status | What the code requires | What the takeoff shows | RRE’s practice |
|---|---|---|---|---|
NEC 2020 110.16 Arc-flash warning label on gear | to check | Switchboards, switchgear, panelboards, meter socket enclosures and motor control centers likely to be worked on energized carry a field- or factory-applied arc-flash hazard warning. | In play for PANELBOARD, CURRENT LIMITING, 120V 1PH 2W, 20-POLE, SURFACE (Lighting Control & Design GR 2400 'The Silverbullet') - panel 'CL'. Nothing on the takeoff shows it. | RRE carries phenolic nameplates and labels as their own item where the set calls for them. |
NEC 2020 210.8(B)(2) GFCI on commercial kitchen receptacles | to check | GFCI protection for every receptacle in a commercial kitchen: single-phase up to 50 A and three-phase up to 100 A, 150 V to ground or less. | 1 of 2 in play are not shown with it: TERMINATION, BRANCH CIRCUIT, 20A 1-POLE. | RRE carries a GFCI receptacle at the device where the set calls for GFCI, and adds none on code alone (Mango: no GFCI bid; The Melt: 25 where the set said so). |
NEC 2020 210.8(B)(1) GFCI on bathroom receptacles | to check | GFCI protection for every receptacle in a bathroom: single-phase up to 50 A and three-phase up to 100 A, 150 V to ground or less. | In play for TERMINATION, BRANCH CIRCUIT, 20A 1-POLE; DUPLEX RECEPTACLE 20A 125V, RESTROOM (B-11); RECEPTACLE 20A 125V DUPLEX, DEDICATED, FOR REFRIGERATED DRINKING FOUNTAIN FX-3 (ELKAY EZTL8C + LKAPREZL), IN 4" SQ BOX. Nothing on the takeoff shows it. |
A takeoff cannot settle every article: load calculations and coordination are the engineer of record’s, and workmanship is the inspector’s. Each is listed so nothing is silently skipped. “Waiting on a code read” means the article is in play and this job’s drawing read has not been checked against the code yet: re-run the read, or check it on the drawings.
| 90 | Introduction | general | Scope and definitions: nothing to check on a job. |
| 100 | Definitions | general | Scope and definitions: nothing to check on a job. |
| 110 | Requirements for Electrical Installations | to check | 1 section checked against the takeoff, 1 to check: 110.16. |
| 200 | Use and Identification of Grounded Conductors | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 210 | Branch Circuits | to check | 5 sections checked against the takeoff, 4 to check: 210.8(B)(2), 210.8(B)(1), 210.8(B), 210.63. |
| 215 | Feeders | checked | In play; none of its checked sections applies to these lines. |
| 220 | Branch-Circuit, Feeder, and Service Load Calculations |
LUTRON PICO WIRELESS DIMMER/SWITCH ('VS' symbol) - install on wall box/mount, vendor furnished The drawings say “vendor furnished”. | Vendor | not stated | RRE installs / connects only | E-300 |
LUTRON VIVE WIRELESS OCCUPANCY SENSOR, CEILING (OS symbol) - install only, vendor furnished The drawings say “vendor furnished”. | Vendor | not stated | RRE installs / connects only | E-300 |
LUTRON VIVE POWPAK RELAY MODULE RMJS-16R-DV-B, INSTALL ONLY (vendor-furnished), ON 4-SQ J-BOX The drawings say “vendor-furnished”. | Vendor | not stated | RRE installs / connects only | E-900 |
LUTRON VIVE HUB HJS-1, INSTALL ONLY (vendor-furnished), ON 4X4 J-BOX W/ 120V FEED The drawings say “vendor-furnished”. | Vendor | not stated | RRE installs / connects only | E-900 |
TENANT ELECTRIC SUBMETER, QUADLOGIC RSM5 OR S20 (landlord-specified), for main tenant electrical system The drawings say “furnished by landlord or tenant”. | Landlord | not stated | RRE installs / connects only | 000-Copy-of-2498-A-set-2025-0530-Revision-1-p1 |
RECEPTACLE 20A 125V DUPLEX, DEDICATED, FOR REFRIGERATED DRINKING FOUNTAIN FX-3 (ELKAY EZTL8C + LKAPREZL), IN 4" SQ BOX The drawings say “installed by gc”. | GC | GC | RRE installs / connects only | A-120 |
LOW VOLTAGE BACKBOX, SINGLE-GANG WITH 3/4" EMT STUB, SUBWOOFER (SW) CONNECTION POINT The drawings say “by gc”. | GC | not stated | RRE installs / connects only | A-150 |
BACKBOX, 4" SQUARE x 2-1/8" DEEP WITH 1-GANG MUD RING, WITH 3/4" EMT STUB TO ACCESSIBLE CEILING, PULL STRING - ALARM KEYPAD AT DOOR 05 (SALES SIDE) The drawings say “by tenant”. | Tenant | not stated | RRE installs / connects only | A-500 |
TRACK, LINE-VOLTAGE 120V SINGLE-CIRCUIT, SURFACE/SUSPENDED (tracks 1-7) Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E-300 |
LIGHT FIXTURE TYPE E06W (schedule E06w) Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | Owner | not stated | Struck: not in this bid | A-130 |
LED DRIVER / TRANSFORMER 75W 24VDC CLASS 2, REMOTE MOUNT (XLG-75 series) FOR S02 SCONCES, WITH J-BOX Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | A-130 |
TRANSFORMER / REMOTE LED DRIVER (spec 26-50.23), CONCEALED ABOVE DISPLAY CEILING IN TAPED-IN ACCESS PANEL - INSTALL & CONNECT, WITH 4" SQ J-BOX AND FLEX WHIP Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | GC | not stated | Struck: not in this bid | A-210 |
EXISTING DUCT SMOKE DETECTOR RECONNECTION TO NEW AHU (UNIT SHUTDOWN INTERLOCK), EXISTING DETECTOR TO REMAIN Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | M-300 |
LED REMOTE TRANSFORMER / DRIVER, CLASS 2, CONCEALED IN MILLWORK CABINET (spec 26-50.23) Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | A-410 |
JUNCTION BOX 4" SQ, 120V FEED TO REMOTE LED TRANSFORMER IN MILLWORK Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | A-410 |
| pass |
Every line points at an assembly. |
| Plan and schedule agree | pass | No line has a plan/schedule disagreement. |
| Lines accepted by a person | blocker | Nothing has been accepted. All 112 line(s) are still suggestions, and machine output is a suggestion until a named person accepts it. Accept on the Takeoff screen — 112 line(s) are ready. |
| Engineer conventions known | pass | No engineer-dependent lines. |
| Unsure flags resolved | pass | The model raised no open flags. |
| Cover sheet read | pass | A cover sheet was found and read; its notes parameterise every later pass. |
| RRE carries GFCI at the device where the set calls for it. |
NEC 2020 210.8(B) GFCI near sinks, in locker rooms, wet and damp locations | to check | GFCI protection for receptacles within 6 ft of a sink, in locker rooms with showers, in indoor wet or damp locations, and in garages, service bays and similar areas. | In play for TERMINATION, BRANCH CIRCUIT, 20A 1-POLE. Nothing on the takeoff shows it. | — |
NEC 2020 210.63 Service receptacle at HVAC equipment | to check | A 125-volt, 15- or 20-ampere receptacle on the same level and within 25 ft of heating, air-conditioning and refrigeration equipment, not on the load side of the equipment disconnect. | In play for #6 THHN CU WIRE, AHU FEEDS; #10 THHN CU WIRE, EQUIPMENT GROUND (AHU/CU); 3/4" EMT CONDUIT, CU FEEDS (ROOF); and 11 more. Nothing on the takeoff shows it. | RRE carries the roof receptacle where the set draws one (reading check 11). |
NEC 2020 300.21 Firestopping at rated penetrations | to check | Electrical penetrations of fire-resistance-rated walls, partitions, floors or ceilings firestopped by an approved method that keeps the rating. | In play for TENMAT FIRE-RATED COVER OVER RECESSED DOWNLIGHT. Nothing on the takeoff shows it. | — |
NEC 2020 300.11, 410.36(B) Support in suspended ceilings | to check | Raceways, cables and boxes above a suspended ceiling are supported independently of the ceiling grid, or by identified support wires; lay-in luminaires are fastened to the grid framing. | In play for LIGHT FIXTURE TYPE QA (schedule QA); LIGHT FIXTURE TYPE QA/EM (schedule QA/EM). Nothing on the takeoff shows it. | RRE carries the fixture support wire as its own item where the ceiling is a grid. |
NEC 2020 422.5(A) GFCI on drinking water coolers, bottle fillers and vending machines | to check | GFCI protection for the appliances 422.5(A) lists, among them drinking water coolers, bottle fill stations, vending machines and high-pressure spray washers. | In play for RECEPTACLE 20A 125V DUPLEX, DEDICATED, FOR REFRIGERATED DRINKING FOUNTAIN FX-3 (ELKAY EZTL8C + LKAPREZL), IN 4" SQ BOX. Nothing on the takeoff shows it. | — |
NEC 2020 210.62 Receptacles in show windows | shown | At least one 125-volt receptacle within 18 in. of the top of a show window for each 12 linear ft of show window. | In play for RECEPTACLE AT WINDOW DISPLAY, LABELLED CLG / FLR (A-6). Shown: RECEPTACLE AT WINDOW DISPLAY, LABELLED CLG / FLR (A-6). | — |
NEC 2020 408.4(A) Circuit directory at every panel | shown | Every circuit and circuit modification legibly identified as to its clear, evident and specific purpose on a circuit directory at the panel. | In play for PANELBOARD, CURRENT LIMITING, 120V 1PH 2W, 20-POLE, SURFACE (Lighting Control & Design GR 2400 'The Silverbullet') - panel 'CL'. Shown: PANEL DIRECTORY, TYPED. | RRE carries a panel directory update where circuits land in an existing panel. |
NEC 2020 440.14 Disconnect within sight of HVAC equipment | shown | A disconnecting means within sight from, and readily accessible from, air-conditioning and refrigerating equipment. It may be on or in the unit. | In play for #6 THHN CU WIRE, AHU FEEDS; #10 THHN CU WIRE, EQUIPMENT GROUND (AHU/CU); 3/4" EMT CONDUIT, CU FEEDS (ROOF); and 11 more. Shown: DISCONNECT SWITCH, 30A 3-POLE 480V NON-FUSED, NEMA 3R - CU-1, CU-2 (roof); DISCONNECT SWITCH, 30A 3-POLE 480V NON-FUSED, NEMA 3R (drawn WP) - AHU-1, AHU-2; EQUIPMENT CONNECTION, OUTDOOR, LIQUIDTIGHT FLEX WHIP 3/4" W/ 3#12 + #12G - CU-1; and 1 more. | RRE priced this on 5 of 5 past jobs (100%). No past remodel jobs on record, so across all 5. RRE carries a disconnect at every unit with a disconnect symbol or note, sized from its circuit. |
NEC 2020 422.31, 424.19, 430.102 Disconnect for water heaters, heaters, fans and motor loads | shown | A disconnect within sight of the appliance, heater or motor, or a branch-circuit breaker that can be locked in the open position. | In play for JUNCTION BOX 4" SQ, WITH $T MOTOR-RATED SWITCH (B-5 MOTORIZED DAMPER / CV); MOTOR-RATED SWITCH $T WITH THERMAL OVERLOAD; EQUIPMENT CONNECTION, CONDENSATE PUMP (CP); and 4 more. Shown: DISCONNECT SWITCH, MOTOR-RATED TOGGLE, 1-POLE 20A 120V - EX-FX-1; DISCONNECT SWITCH, 30A 2-POLE 240V NON-FUSED, NEMA 1 (indoor) - EWH / WH-1 (AO Smith DEL-10, 2.5 kW 208V 1PH). | A lockable breaker answers it as well as a switch: check the panel schedule before adding a disconnect. |
NEC 2020 600.5(A) Sign outlet at each tenant entrance | shown | At least one outlet at each entrance to each tenant space accessible to pedestrians, for a sign, on a 20-ampere branch circuit that supplies no other load. | Shown: TERMINATION, BRANCH CIRCUIT, 20A 1-POLE; JUNCTION BOX 4" SQ AT SIGNAGE, WITH $T SWITCH; TOGGLE SWITCH, $T (SIGNAGE). | RRE prices "power to building signage" where the set shows it; the matrix row is left blank where it does not. |
NEC 2020 600.6 Disconnect within sight of a sign | shown | Each sign or outline lighting system, or its feeder, has an externally operable disconnect within sight of the sign, or one capable of being locked in the open position. | In play for TERMINATION, BRANCH CIRCUIT, 20A 1-POLE; JUNCTION BOX 4" SQ AT SIGNAGE, WITH $T SWITCH; TOGGLE SWITCH, $T (SIGNAGE). Shown: DISCONNECT SWITCH, 30A 3-POLE 480V NON-FUSED, NEMA 3R - CU-1, CU-2 (roof); DISCONNECT SWITCH, 30A 3-POLE 480V NON-FUSED, NEMA 3R (drawn WP) - AHU-1, AHU-2; BREAKER LOCK-ON DEVICE; and 4 more. | RRE prices a WP switch at signage as a fused disconnect assembly (firm practice wp_switch_mapping). |
NEC 2020 Chapter 9 Table 1, 358.22 Conduit fill | shown | Over two conductors, a raceway is filled to no more than 40 % of its internal area (Chapter 9 Tables 1, 4 and 5; THHN conductors, EMT). | All 4 callouts naming conductors and conduit are within it. | — |
| design |
| The engineer of record’s: sizing, calculation or coordination, not checked against a takeoff. |
| 225 | Outside Branch Circuits and Feeders | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 230 | Services | checked | In play; none of its checked sections applies to these lines. |
| 240 | Overcurrent Protection | checked | In play; none of its checked sections applies to these lines. |
| 242 | Overvoltage Protection | not in play | Nothing on this takeoff puts it in play. |
| 250 | Grounding and Bonding | checked | In play; none of its checked sections applies to these lines. |
| 300 | General Requirements for Wiring Methods and Materials | to check | 2 sections checked against the takeoff, 2 to check: 300.21, 300.11, 410.36(B). |
| 310 | Conductors for General Wiring | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 311 | Medium Voltage Conductors and Cable | not in play | Nothing on this takeoff puts it in play. |
| 312 | Cabinets, Cutout Boxes, and Meter Socket Enclosures | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 314 | Outlet, Device, Pull, and Junction Boxes; Conduit Bodies; Fittings; and Handhole Enclosures | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 320 | Armored Cable: Type AC | not in play | Nothing on this takeoff puts it in play. |
| 322 | Flat Cable Assemblies: Type FC | not in play | Nothing on this takeoff puts it in play. |
| 324 | Flat Conductor Cable: Type FCC | not in play | Nothing on this takeoff puts it in play. |
| 326 | Integrated Gas Spacer Cable: Type IGS | not in play | Nothing on this takeoff puts it in play. |
| 330 | Metal-Clad Cable: Type MC | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 332 | Mineral-Insulated, Metal-Sheathed Cable: Type MI | not in play | Nothing on this takeoff puts it in play. |
| 334 | Nonmetallic-Sheathed Cable: Types NM and NMC | not in play | Nothing on this takeoff puts it in play. |
| 336 | Power and Control Tray Cable: Type TC | not in play | Nothing on this takeoff puts it in play. |
| 337 | Type P Cable | not in play | Nothing on this takeoff puts it in play. |
| 338 | Service-Entrance Cable: Types SE and USE | not in play | Nothing on this takeoff puts it in play. |
| 340 | Underground Feeder and Branch-Circuit Cable: Type UF | not in play | Nothing on this takeoff puts it in play. |
| 342 | Intermediate Metal Conduit: Type IMC | not in play | Nothing on this takeoff puts it in play. |
| 344 | Rigid Metal Conduit: Type RMC | not in play | Nothing on this takeoff puts it in play. |
| 348 | Flexible Metal Conduit: Type FMC | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 350 | Liquidtight Flexible Metal Conduit: Type LFMC | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 352 | Rigid Polyvinyl Chloride Conduit: Type PVC | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 353 | High Density Polyethylene Conduit: Type HDPE Conduit | not in play | Nothing on this takeoff puts it in play. |
| 354 | Nonmetallic Underground Conduit with Conductors: Type NUCC | not in play | Nothing on this takeoff puts it in play. |
| 355 | Reinforced Thermosetting Resin Conduit: Type RTRC | not in play | Nothing on this takeoff puts it in play. |
| 356 | Liquidtight Flexible Nonmetallic Conduit: Type LFNC | not in play | Nothing on this takeoff puts it in play. |
| 358 | Electrical Metallic Tubing: Type EMT | checked | In play; none of its checked sections applies to these lines. |
| 360 | Flexible Metallic Tubing: Type FMT | not in play | Nothing on this takeoff puts it in play. |
| 362 | Electrical Nonmetallic Tubing: Type ENT | not in play | Nothing on this takeoff puts it in play. |
| 366 | Auxiliary Gutters | not in play | Nothing on this takeoff puts it in play. |
| 368 | Busways | not in play | Nothing on this takeoff puts it in play. |
| 369 | Insulated Bus Pipe (IBP)/Tubular Covered Conductors (TCC) Systems | not in play | Nothing on this takeoff puts it in play. |
| 370 | Cablebus | not in play | Nothing on this takeoff puts it in play. |
| 371 | Flexible Bus Systems | not in play | Nothing on this takeoff puts it in play. |
| 372 | Cellular Concrete Floor Raceways | not in play | Nothing on this takeoff puts it in play. |
| 374 | Cellular Metal Floor Raceways | not in play | Nothing on this takeoff puts it in play. |
| 376 | Metal Wireways | not in play | Nothing on this takeoff puts it in play. |
| 378 | Nonmetallic Wireways | not in play | Nothing on this takeoff puts it in play. |
| 380 | Multioutlet Assembly | not in play | Nothing on this takeoff puts it in play. |
| 382 | Nonmetallic Extensions | not in play | Nothing on this takeoff puts it in play. |
| 384 | Strut-Type Channel Raceway | not in play | Nothing on this takeoff puts it in play. |
| 386 | Surface Metal Raceways | not in play | Nothing on this takeoff puts it in play. |
| 388 | Surface Nonmetallic Raceways | not in play | Nothing on this takeoff puts it in play. |
| 390 | Underfloor Raceways | not in play | Nothing on this takeoff puts it in play. |
| 392 | Cable Trays | not in play | Nothing on this takeoff puts it in play. |
| 393 | Low-Voltage Suspended Ceiling Power Distribution Systems | not in play | Nothing on this takeoff puts it in play. |
| 394 | Concealed Knob-and-Tube Wiring | not in play | Nothing on this takeoff puts it in play. |
| 396 | Messenger-Supported Wiring | not in play | Nothing on this takeoff puts it in play. |
| 398 | Open Wiring on Insulators | not in play | Nothing on this takeoff puts it in play. |
| 399 | Outdoor, Overhead Conductors over 1000 Volts | not in play | Nothing on this takeoff puts it in play. |
| 400 | Flexible Cords and Flexible Cables | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 402 | Fixture Wires | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 404 | Switches | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 406 | Receptacles, Cord Connectors, and Attachment Plugs (Caps) | checked | In play; none of its checked sections applies to these lines. |
| 408 | Switchboards, Switchgear, and Panelboards | checked | 1 section checked against the takeoff, all shown. |
| 409 | Industrial Control Panels | not in play | Nothing on this takeoff puts it in play. |
| 410 | Luminaires, Lampholders, and Lamps | checked | In play; none of its checked sections applies to these lines. |
| 411 | Low-Voltage Lighting | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 422 | Appliances | to check | 2 sections checked against the takeoff, 1 to check: 422.5(A). |
| 424 | Fixed Electric Space-Heating Equipment | not in play | Nothing on this takeoff puts it in play. |
| 425 | Fixed Resistance and Electrode Industrial Process Heating Equipment | not in play | Nothing on this takeoff puts it in play. |
| 426 | Fixed Outdoor Electric Deicing and Snow-Melting Equipment | not in play | Nothing on this takeoff puts it in play. |
| 427 | Fixed Electric Heating Equipment for Pipelines and Vessels | not in play | Nothing on this takeoff puts it in play. |
| 430 | Motors, Motor Circuits, and Controllers | checked | In play; none of its checked sections applies to these lines. |
| 440 | Air-Conditioning and Refrigerating Equipment | checked | 1 section checked against the takeoff, all shown. |
| 445 | Generators | not in play | Nothing on this takeoff puts it in play. |
| 450 | Transformers and Transformer Vaults (Including Secondary Ties) | not in play | Nothing on this takeoff puts it in play. |
| 455 | Phase Converters | not in play | Nothing on this takeoff puts it in play. |
| 460 | Capacitors | not in play | Nothing on this takeoff puts it in play. |
| 470 | Resistors and Reactors | not in play | Nothing on this takeoff puts it in play. |
| 480 | Stationary Standby Batteries | not in play | Nothing on this takeoff puts it in play. |
| 490 | Equipment Over 1000 Volts, Nominal | not in play | Nothing on this takeoff puts it in play. |
| 500 | Hazardous (Classified) Locations, Classes I, II, and III, Divisions 1 and 2 | not in play | Nothing on this takeoff puts it in play. |
| 501 | Class I Hazardous (Classified) Locations | not in play | Nothing on this takeoff puts it in play. |
| 502 | Class II Hazardous (Classified) Locations | not in play | Nothing on this takeoff puts it in play. |
| 503 | Class III Hazardous (Classified) Locations | not in play | Nothing on this takeoff puts it in play. |
| 504 | Intrinsically Safe Systems | not in play | Nothing on this takeoff puts it in play. |
| 505 | Zone 0, 1, and 2 Locations | not in play | Nothing on this takeoff puts it in play. |
| 506 | Zone 20, 21, and 22 Locations for Combustible Dusts or Ignitible Fibers/Flyings | not in play | Nothing on this takeoff puts it in play. |
| 510 | Hazardous (Classified) Locations — Specific | not in play | Nothing on this takeoff puts it in play. |
| 511 | Commercial Garages, Repair and Storage | not in play | Nothing on this takeoff puts it in play. |
| 513 | Aircraft Hangars | not in play | Nothing on this takeoff puts it in play. |
| 514 | Motor Fuel Dispensing Facilities | not in play | Nothing on this takeoff puts it in play. |
| 515 | Bulk Storage Plants | not in play | Nothing on this takeoff puts it in play. |
| 516 | Spray Application, Dipping, Coating, and Printing Processes | not in play | Nothing on this takeoff puts it in play. |
| 517 | Health Care Facilities | not in play | Nothing on this takeoff puts it in play. |
| 518 | Assembly Occupancies | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 520 | Theaters, Audience Areas of Motion Picture and Television Studios, Performance Areas, and Similar Locations | not in play | Nothing on this takeoff puts it in play. |
| 522 | Control Systems for Permanent Amusement Attractions | not in play | Nothing on this takeoff puts it in play. |
| 525 | Carnivals, Circuses, Fairs, and Similar Events | not in play | Nothing on this takeoff puts it in play. |
| 530 | Motion Picture and Television Studios and Similar Locations | not in play | Nothing on this takeoff puts it in play. |
| 540 | Motion Picture Projection Rooms | not in play | Nothing on this takeoff puts it in play. |
| 545 | Manufactured Buildings and Relocatable Structures | not in play | Nothing on this takeoff puts it in play. |
| 547 | Agricultural Buildings | not in play | Nothing on this takeoff puts it in play. |
| 550 | Mobile Homes, Manufactured Homes, and Mobile Home Parks | not in play | Nothing on this takeoff puts it in play. |
| 551 | Recreational Vehicles and Recreational Vehicle Parks | not in play | Nothing on this takeoff puts it in play. |
| 552 | Park Trailers | not in play | Nothing on this takeoff puts it in play. |
| 555 | Marinas, Boatyards, Floating Buildings, and Commercial and Noncommercial Docking Facilities | not in play | Nothing on this takeoff puts it in play. |
| 590 | Temporary Installations | not in play | Nothing on this takeoff puts it in play. |
| 600 | Electric Signs and Outline Lighting | checked | 2 sections checked against the takeoff, all shown. |
| 604 | Manufactured Wiring Systems | not in play | Nothing on this takeoff puts it in play. |
| 605 | Office Furnishings | not in play | Nothing on this takeoff puts it in play. |
| 610 | Cranes and Hoists | not in play | Nothing on this takeoff puts it in play. |
| 620 | Elevators, Dumbwaiters, Escalators, Moving Walks, Platform Lifts, and Stairway Chairlifts | not in play | Nothing on this takeoff puts it in play. |
| 625 | Electric Vehicle Power Transfer System | not in play | Nothing on this takeoff puts it in play. |
| 626 | Electrified Truck Parking Spaces | not in play | Nothing on this takeoff puts it in play. |
| 630 | Electric Welders | not in play | Nothing on this takeoff puts it in play. |
| 640 | Audio Signal Processing, Amplification, and Reproduction Equipment | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 645 | Information Technology Equipment | not in play | Nothing on this takeoff puts it in play. |
| 646 | Modular Data Centers | not in play | Nothing on this takeoff puts it in play. |
| 647 | Sensitive Electronic Equipment | not in play | Nothing on this takeoff puts it in play. |
| 650 | Pipe Organs | not in play | Nothing on this takeoff puts it in play. |
| 660 | X-Ray Equipment | not in play | Nothing on this takeoff puts it in play. |
| 665 | Induction and Dielectric Heating Equipment | not in play | Nothing on this takeoff puts it in play. |
| 668 | Electrolytic Cells | not in play | Nothing on this takeoff puts it in play. |
| 669 | Electroplating | not in play | Nothing on this takeoff puts it in play. |
| 670 | Industrial Machinery | not in play | Nothing on this takeoff puts it in play. |
| 675 | Electrically Driven or Controlled Irrigation Machines | not in play | Nothing on this takeoff puts it in play. |
| 680 | Swimming Pools, Fountains, and Similar Installations | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 682 | Natural and Artificially Made Bodies of Water | not in play | Nothing on this takeoff puts it in play. |
| 685 | Integrated Electrical Systems | not in play | Nothing on this takeoff puts it in play. |
| 690 | Solar Photovoltaic (PV) Systems | not in play | Nothing on this takeoff puts it in play. |
| 691 | Large-Scale Photovoltaic (PV) Electric Supply Stations | not in play | Nothing on this takeoff puts it in play. |
| 692 | Fuel Cell Systems | not in play | Nothing on this takeoff puts it in play. |
| 694 | Wind Electric Systems | not in play | Nothing on this takeoff puts it in play. |
| 695 | Fire Pumps | not in play | Nothing on this takeoff puts it in play. |
| 700 | Emergency Systems | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 701 | Legally Required Standby Systems | not in play | Nothing on this takeoff puts it in play. |
| 702 | Optional Standby Systems | not in play | Nothing on this takeoff puts it in play. |
| 705 | Interconnected Electric Power Production Sources | not in play | Nothing on this takeoff puts it in play. |
| 706 | Energy Storage Systems | not in play | Nothing on this takeoff puts it in play. |
| 708 | Critical Operations Power Systems (COPS) | not in play | Nothing on this takeoff puts it in play. |
| 710 | Stand-Alone Systems | not in play | Nothing on this takeoff puts it in play. |
| 712 | Direct Current Microgrids | not in play | Nothing on this takeoff puts it in play. |
| 720 | Circuits and Equipment Operating at Less Than 50 Volts | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 725 | Class 1, Class 2, and Class 3 Remote-Control, Signaling, and Power-Limited Circuits | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 727 | Instrumentation Tray Cable: Type ITC | not in play | Nothing on this takeoff puts it in play. |
| 728 | Fire-Resistive Cable Systems | not in play | Nothing on this takeoff puts it in play. |
| 750 | Energy Management Systems | not in play | Nothing on this takeoff puts it in play. |
| 760 | Fire Alarm Systems | checked | In play; none of its checked sections applies to these lines. |
| 770 | Optical Fiber Cables | not in play | Nothing on this takeoff puts it in play. |
| 800 | General Requirements for Communications Systems | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 805 | Communications Circuits | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 810 | Radio and Television Antenna Equipment | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 820 | Community Antenna Television and Radio Distribution Systems | not in play | Nothing on this takeoff puts it in play. |
| 830 | Network-Powered Broadband Communications Systems | not in play | Nothing on this takeoff puts it in play. |
| 840 | Premises-Powered Broadband Communications Systems | not in play | Nothing on this takeoff puts it in play. |
| Ch. 9 | Tables: conduit fill, conductor properties, power-limited sources | checked | 1 section checked against the takeoff, all shown. |