Derived from what the read produced, so none of it can drift from the data behind it. A blocker stops a price being presented as complete; it never stops you looking. These definitions are this build’s own — no RRE document specifies them yet.
| Check | Status | What the check found |
|---|---|---|
| Sheet scale | pass | All 4 plan sheet(s) carry a scale, so measurement is available. The other 11 read sheet(s) are specifications, schedules and details — nothing is measured on them, so a scale on one is not needed and a scale missing from one is not a gap. |
| Sheets read for scope | warning | 38 sheet(s) were indexed but not read for scope: 000-Copy-of-Drawings-p1, 000-Copy-of-Drawings-p2, 000-Copy-of-Drawings-p3, 000-Copy-of-Drawings-p4, 000-Copy-of-Drawings-p5, SD0, C1, C2, C3, C4, A1.5, A3.1, A3.2, A5.1, A5.3, 000-Copy-of-Drawings-p24, 000-Copy-of-Drawings-p25, 000-Copy-of-Drawings-p26, 000-Copy-of-Drawings-p27, 000-Copy-of-Drawings-p29, 000-Copy-of-Drawings-p30, SN2, SN3, S1, S2, DS2, DS4, M0.1, M0.3, M0.4, M0.5, P0.1, P0.2, P2.0, P2.1, P3.1, P4.1, P4.2. Looked at by the takeoff and not read: no electrical work on it. Read them, or state the omission on the proposal — the basis of the offer already prints it. |
| Symbol source | pass | A symbol list was found on the drawings: E1.0 — ELECTRICAL GENERAL NOTES, LEGEND & SYMBOLS. The project legend is authoritative for this set and outranks everything else — NECA 100-2006 itself allows a drawing to use non-standard symbols provided the legend explains them. NECA 100-2006 stays underneath it for anything the legend leaves silent, and no conventions file exists for MATRISCOPE ENGINEERING. |
| Symbols named | pass | All 21462 marks belong to a named group. |
| Every line prices | pass | Every line points at an assembly. |
| Plan and schedule agree | pass | No line has a plan/schedule disagreement. |
| Lines accepted by a person | pass | All 93 eligible line(s) accepted. |
| Engineer conventions known | pass | MATRISCOPE ENGINEERING has a conventions file. |
| Unsure flags resolved | pass | The model raised no open flags. |
| Cover sheet read | pass | A cover sheet was found and read; its notes parameterise every later pass. |
What the symbol names rest on. The set’s own legend (E1.0), which is authoritative for this project.
Edition: 2025 California Electrical Code, because in force for permits from 2026-01-01, as of the bid date 2026-09-30. City and county amendments are the AHJ’s: check them on any job inside a city that amends the code. “To check” means the code requires it and the drawings do not show it: send an RFI, or make the call. Nothing here is added to the bid on its own.
| Section | Status | What the code requires | What the takeoff shows | RRE’s practice |
|---|---|---|---|---|
NEC 2023 110.24 Available fault current marked at the service | to check | Service equipment in other than dwelling units is field-marked with the maximum available fault current and the date it was calculated. | In play for MAIN SWITCHBOARD MSB 800A 208Y/120V 3PH 4W NEMA 3R 65 KAIC, 800A 3P 100% RATED MAIN, (1) 200A 3P DISTRIBUTION BREAKER, (4) SPACES FOR FUTURE PANEL. Nothing on the takeoff shows it. | — |
NEC 2023 250.94 Intersystem bonding termination | to check | An intersystem bonding termination at the service equipment or metering, for the communications, CATV and broadband systems to bond to. | In play for MAIN SWITCHBOARD MSB 800A 208Y/120V 3PH 4W NEMA 3R 65 KAIC, 800A 3P 100% RATED MAIN, (1) 200A 3P DISTRIBUTION BREAKER, (4) SPACES FOR FUTURE PANEL. Nothing on the takeoff shows it. | — |
NEC 2023 300.11, 410.36(B) Support in suspended ceilings | to check | Raceways, cables and boxes above a suspended ceiling are supported independently of the ceiling grid, or by identified support wires; lay-in luminaires are fastened to the grid framing. | In play for LIGHT FIXTURE TYPE A - 1X4 SUSPENDED LED 44W 120V DIMMABLE (0-10V), LSI SW-4-60L-840-UNV-EM OR EQUAL. Nothing on the takeoff shows it. | RRE carries the fixture support wire as its own item where the ceiling is a grid. |
The RRE item carries no price for the part named, so the estimate has the install labor and rough-in only, and the vendor or sub prices the rest. Send the lighting and gear lists from Material list & vendor quotes.
| Line | Needs a price for | Count | Sheet |
|---|---|---|---|
LIGHT FIXTURE TYPE C - EXTERIOR WALL SCONCE 55W 120V, LSI XPWS3-WT-LED-48-350-UE-PCI120 OR EQUAL Exterior W wall and S wall, circuit H-5c | LED WALL SCONCE - MED | 2 ea | E4.0 |
LIGHT FIXTURE TYPE D - WALL MOUNTED LED 16W 120V, LSI SW-2-20L-830-UNV OR EQUAL Back room at SW door, circuit H-1e | LED WALL SCONCE - MED | 1 ea | E4.0 |
| Line | Needs a price for | Count | Sheet |
|---|---|---|---|
TITLE 24 LIGHTING CONTROLS ACCEPTANCE TEST NRCA-LTI-02-A (INDOOR - OCCUPANCY SENSORS & AUTOMATIC TIME SWITCH CONTROLS, CERTIFIED ATT) Tenant space; per NRCC-LTI-E Section V, completed through an ATTCP-certified acceptance test technician | POWER PACK 120/277V-24V | 1 ea | E2.1 |
Read off the schedules and notes. RRE buys none of the material named here. Check each against the responsibility matrix on the proposal: these are what it should say is by others.
| Line | Furnished by | Installed by |
|---|
14 lines the reader wrote at zero are not listed: they add nothing to the bid.
From the same raceway model run: 3 x #12 per circuit (GN22 separate neutral per phase conductor), each circuit's wire running the shared home-run pipe plus its own chain and drops, rescaled from 18 to 13.5 pt/ft: 1619 ft. MODELLED from untagged fixtures. (Model line id L-0088.)
House: 3 conductors per circuit x run, nothing added. H-15 111.7 + H-13 92.7 + H-9 3.0 ft = 207.5 ft x 3. All runs <100 ft so #12 (E7.0 2.02). MODELLED. (Model line id L-0072.)
EV-1 and EV-2 callouts 1"C (2)#6 AWG & (1)#10 GND (E1.1 equipment schedule, H-14,16 / H-18,20): 2 conductors x (underground run + exposed run) = 2x(139.4+125.4). No makeup (house). (Model line id L-0048.)
STRUCK IN STEP 4.5 (was 490 ft): duplicate across sheets of L-0048, which carries the same item. EV-1/EV-2 #6 conductors, E1.1 measurement governs. Quantity set to 0 rather than deleted so the strike is visible; restoring this line would count the item twice. Original reading: Two #6 conductors on each of the EV-1 (130 ft) and EV-2 (115 ft) feeders per the E5.0 callouts: 2 x (130+115) = 490 ft. (Model line id L-0101.) The model also raised 'struck-duplicate', which the contract has no flag for; recorded here rather than dropped.
MODELLED from untagged fixtures: the E4.0 circuit tags are drawn as outline lettering and the raceway model read 0 tags, so it was run with panel H located on the page (246,669 pt) and --untagged-panel H --untagged-circuits 4 (H-1, H-3, H-5, H-7 lighting circuits off circuits.json) over the 21 fixtures read off the plan as stops. Chain in EMT + THHN (job-facts: MC fixture chain barred, spec 16050 3.02.A all wiring in raceway). The model found no scale on the sheet and measured at its 18 pt/ft default; its home-run and chain lengths were rescaled to the title's 3/16"=1'-0" (13.5 pt/ft), drops left at the model's 2 ft per fixture: 418 ft. Exterior runs to B/C/H-7 fixtures in the concrete wall may need rigid per E3.0 SN9 - see coverage gaps. The measurements drawn on the sheet are each circuit's own Manhattan route from panel H (together about 621 ft, because every circuit is drawn from the panel); the line carries the model's figure, where up to three circuits share one home-run pipe. (Model line id L-0087.)
Callout '1"C (3)#4 AWG & (1)#10 GND' on each AC unit: 3 x (34.2 + 67.5) ft. Riser not included. MODELLED. (Model line id L-0074.)
(1)#10 GND per each EV feeder callout on E1.1, over each run: 139.4+125.4+28.2. (Model line id L-0050.)
Feeder callouts H-14,16 / H-18,20 / H-22,24 are drawn only as homerun arrows on the enlarged plans; the route was measured on the 1 ELECTRICAL SITE PLAN (3/32"=1'-0", 6.75 pt/ft) Manhattan from (N) PANEL 'H' to each charger location: EV-1 134 ft, EV-2 120 ft, EV-3 23 ft. E5.0 feeder lengths ~130/115/35 ft agree on EV-1/EV-2; EV-3 measures shorter (23 v 35). 1"C per each unit's callout. Underground PVC SCH 40 per E1.1 SN1; SN4 routes diagrammatic. The raceway model read 0 tags (lettering drawn as outlines, views at two scales), so this is a modelled measurement. No waste (house). (Model line id L-0046.)
STRUCK IN STEP 4.5 (was 260 ft): duplicate across sheets of L-0048, which carries the same item. EV-1 #6 conductors, E1.1 measurement governs. Quantity set to 0 rather than deleted so the strike is visible; restoring this line would count the item twice. Original reading: 2 conductors x 130 ft per one-line. (Model line id L-0031.) The model also raised 'struck-duplicate', which the contract has no flag for; recorded here rather than dropped.
STRUCK IN STEP 4.5 (was 240 ft): duplicate across sheets of L-0052, which carries the same item. #3/0 feeder conductors MSB to H; E1.1 measured route governs. Quantity set to 0 rather than deleted so the strike is visible; restoring this line would count the item twice. Original reading: Four #3/0 conductors in the 60 ft MSB-to-H conduit per the E5.0 single-line callout '(N) 2"C-(4)#3/0 AWG & (1)#6 CU. GND LENGTH≈60FT.': 4 x 60 = 240 ft, before makeup allowance. (Model line id L-0098.) The model also raised 'struck-duplicate', which the contract has no flag for; recorded here rather than dropped.
STRUCK IN STEP 4.5 (was 230 ft): duplicate across sheets of L-0048, which carries the same item. EV-2 #6 conductors, E1.1 measurement governs. Quantity set to 0 rather than deleted so the strike is visible; restoring this line would count the item twice. Original reading: 2 conductors x 115 ft per one-line. (Model line id L-0034.) The model also raised 'struck-duplicate', which the contract has no flag for; recorded here rather than dropped.
Trench along the measured routes: EV-1 path 134 ft (EV-2 shares it), EV-3 23 ft, MSB-H 41 ft, PG&E secondary 27 ft. Modelled from the schematic site plan (GN1, SN4 diagrammatic); detail 4 PG&E joint trench governs separation. Who trenches (EC/GC/PG&E) is not stated. (Model line id L-0056.) The model also raised 'trench_responsibility_not_stated', which the contract has no flag for; recorded here rather than dropped.
3 x 67.6 ft H-11 roof run. MODELLED. (Model line id L-0073.)
(4)#3/0 CU per E5.0 feeder to panel H over the 41 ft measured on E1.1. If the E1.1 '(3)2"C' is right (parallel sets), conductors change -- see coverage. (Model line id L-0052.)
STRUCK IN STEP 4.5 (was 130 ft): duplicate across sheets of L-0050, which carries the same item. EV-1 #10 ground, E1.1 measurement governs. Quantity set to 0 rather than deleted so the strike is visible; restoring this line would count the item twice. Original reading: 1 EGC x 130 ft per one-line. (Model line id L-0032.) The model also raised 'struck-duplicate', which the contract has no flag for; recorded here rather than dropped.
Hand-modelled on E3.0 plan 1 at 3/16"=1'-0" (13.5 pt/ft, title block): Manhattan route along walls from panel H (W wall) to the north storefront, H-13 and H-15 sharing one homerun (house: up to 3 ckts per pipe) 79.3 ft to the first show-window receptacle, then H-13 on to the WP J-box and H-15 on to the east receptacle; H-9 3.0 ft to the quad. No rise/stub/waste (house raceway_practice). Size 3/4" from the drawn '(N) (1)3/4"C'. raceway_model.py read 0 tags (lettering is outlined); measured by hand. MODELLED footage. Device drops in EMT (spec barred MC). (Model line id L-0069.)
STRUCK IN STEP 4.5 (was 115 ft): duplicate across sheets of L-0050, which carries the same item. EV-2 #10 ground, E1.1 measurement governs. Quantity set to 0 rather than deleted so the strike is visible; restoring this line would count the item twice. Original reading: 1 EGC x 115 ft per one-line. (Model line id L-0035.) The model also raised 'struck-duplicate', which the contract has no flag for; recorded here rather than dropped.
1 x (34.2 + 67.5) ft per the AC callouts. MODELLED. (Model line id L-0075.)
Added by kelchlin from a suggestion -- quantity 98 ea ESTIMATED from RRE's ratio, not measured: RRE priced this on 4 of 4 past jobs (100%). RRE’s last restaurant job: 805 straps on 3,183 ft of 3/4" EMT (one per 4 ft); its last retail job 764 on 2,142 ft (one per 2.8 ft). The EMT item carries one per 8 ft, so 0.18 a foot more. Recommended: RRE-EMT-STRAP at 0.03 hr each.
STRUCK IN STEP 4.5 (was 70 ft): duplicate across sheets of L-0049, which carries the same item. EV-3 #8 conductors, E1.1 measurement governs. Quantity set to 0 rather than deleted so the strike is visible; restoring this line would count the item twice. Original reading: Two #8 conductors on the 35 ft EV-3 feeder per the E5.0 callout: 2 x 35 = 70 ft. (Model line id L-0102.) The model also raised 'struck-duplicate', which the contract has no flag for; recorded here rather than dropped.
Hand-modelled on E3.0 roof plan: panel H to the H-11 GFCI,WP at AC-1 then chained to the one at AC-2, Manhattan, no waste. 3/4" default. SN9 rigid steel. MODELLED footage. (Model line id L-0071.)
STRUCK IN STEP 4.5 (was 60 ft): duplicate across sheets of L-0051, which carries the same item. MSB-to-panel H 2" PVC: E5.0 one-line gives no length (60 ft allowance); E1.1 site plan measures the route at 41 ft, which governs. Quantity set to 0 rather than deleted so the strike is visible; restoring this line would count the item twice. Original reading: E5.0 one-line: (N) 2"C-(4)#3/0 & (1)#6 CU GND LENGTH~60FT VD 0.70%; E1.1 SN1 underground PVC SCH40 with rigid PVC-coated elbows. (Model line id L-0004.) The model also raised 'E1.1 site plan labels this run (N) (3)2"C - one vs three conduits unresolved', 'struck-duplicate', which the contract has no flag for; recorded here rather than dropped.
STRUCK IN STEP 4.5 (was 60 ft): duplicate across sheets of L-0053, which carries the same item. #6 ground MSB to H; E1.1 measured route governs. Quantity set to 0 rather than deleted so the strike is visible; restoring this line would count the item twice. Original reading: (1)#6 CU GND x 60 ft per one-line. (Model line id L-0007.) The model also raised 'struck-duplicate', which the contract has no flag for; recorded here rather than dropped.
Added by kelchlin from a suggestion -- quantity 58 ft ESTIMATED from RRE's ratio, not measured: RRE priced this on 4 of 4 past jobs (100%). RRE’s last 2 jobs: 2,707 ft of MC luminary 16-2 and 907 ft of 12/3 for 232 whip-fed fixtures (downlights, sconces, emergency, exit, suspended; track heads and strip excluded), measured off the lighting plans as fixture-to-fixture runs. Recommended: RRE-MC-LUM-16-2, priced as RRE bid it at 0.028 hr/ft.
EV-3 callout 1"C (2)#8 AWG & (1)#10 GND (E1.1 equipment schedule, H-22,24): 2 x 28.2 ft. E5.0 gives ~35 ft for this feeder; measured shorter on the site plan. (Model line id L-0049.)
E1.1 site plan draws '(N) (3)2"C TO (N) PANEL "H"' from the (N) 800A MSB to (N) PANEL 'H'; measured Manhattan at 3/32"=1'-0" = 41 ft (E5.0 VD calc uses ~60 ft). Carried as ONE 2" conduit per the E5.0 feeder (4)#3/0 + (1)#6 GND; E1.1 labels (3)2"C -- conflict flagged. May duplicate the E5.0 one-line reader's feeder line: merge, do not add. (Model line id L-0051.) The model also raised 'conflict_E1.1_v_E5.0', which the contract has no flag for; recorded here rather than dropped.
(1)#6 CU GND per E5.0 feeder over the 41 ft measured on E1.1. (Model line id L-0053.)
STRUCK IN STEP 4.5 (was 35 ft): duplicate across sheets of L-0050, which carries the same item. EV-3 #10 ground, E1.1 measurement governs. Quantity set to 0 rather than deleted so the strike is visible; restoring this line would count the item twice. Original reading: 1 EGC x 35 ft per one-line. (Model line id L-0038.) The model also raised 'struck-duplicate', which the contract has no flag for; recorded here rather than dropped.
Added by kelchlin from a suggestion -- quantity 20 ft ESTIMATED from RRE's ratio, not measured: RRE priced this on 4 of 4 past jobs (100%). RRE’s last 2 jobs: 2,707 ft of MC luminary 16-2 and 907 ft of 12/3 for 232 whip-fed fixtures (downlights, sconces, emergency, exit, suspended; track heads and strip excluded), measured off the lighting plans as fixture-to-fixture runs. Recommended: RRE-MC-LUM-12-3, priced as RRE bid it at 0.028 hr/ft.
Added by kelchlin from a suggestion -- quantity 13 ea ESTIMATED from RRE's ratio, not measured: RRE priced this on 4 of 4 past jobs (100%). RRE carries MC connectors in step with its luminary cable. Less the ones its branch MC items already carry, about 478 for 2,760 ft on its last retail job and 141 for 853 ft on its last restaurant job (0.17 a foot). Recommended: RRE-MC-CONNECTOR at 0.05 hr each.
terminations_per_breaker off panel H schedule: 8 x 20A-1P branch circuits H odd 1-15. (Model line id L-0017.)
House rule panel_safe_off: ONE line, 8 hr per job. Note: set shows all-new gear, no existing panels. (Model line id L-0042.) The model also raised 'no existing panel in set - estimator may strike', which the contract has no flag for; recorded here rather than dropped.
Counted 8 emergency-light symbols drawn outside the building line and tagged H-7 (panel H ckt 7 'EMERGENCY LIGHTING - OUTDOOR'): 2 on N wall, 2 on W wall, 1 at NE entry, 1 on E wall, 2 on S wall. Shapes match schedule type X (twin head and bowtie box variants). The schedule has no separate exterior emergency type, so the wet-location rating is flagged for confirmation. (Model line id L-0083.) The model also raised 'confirm wet-location emergency fixture type', which the contract has no flag for; recorded here rather than dropped.
DS1 detail 15 MAIN SWITCHBOARD ATTACHMENT AT SLAB (N.T.S.), plan view: 8 anchor circles drawn, 4 per switchboard section on a 31" x 21" MOUNT DIM. pattern, with note 'PROVIDE 3/8"Ø SIMPSON STRONG-BOLT 2 ANCHORS w/ 2-1/2" NOMINAL EMBED. TO PAD - (1) AT EA. MOUNTING LOCATION PER MECH PLANS, MIN (1) PER CORNER, MIN. 6" ANCHOR DIST. TO EDGE OF CONC.' Section view shows the anchors through the board base into the pad. Only one MSB in the job (E5.0/E1.1, outdoor NW corner), so 8 x 1 place. Setting the switchboard itself is carried on E1.1/E5.0 and is not re-taken here; this line is the anchor material and drilling only. (Model line id L-0116.) The model also raised 'structural sheet -- anchor setting assumed EC as part of setting the switchboard; pad itself not taken (see coverage_gaps)', which the contract has no flag for; recorded here rather than dropped.
Counted 5 interior emergency twin-head symbols (legend symbol X, callout '5 6 X (TYP)') tagged H-3 on E4.0: N wall, W wall at entrance, NE entry, E wall, S wall. SN5 unswitched hot to emergency lights; SN6 verify location/height above door and plate glass. Not in T-24 table (emergency). (Model line id L-0082.)
Counted 4 switch symbols ($) on E4.0 with zone letters b and c at the W entrance, d at the NE entrance and e in the rear room by the SW door. SN3/GN10 verify switch locations with architect/owner. (Model line id L-0084.)
terminations_per_breaker off panel H schedule: EV-1, EV-2, EV-3. (Model line id L-0020.)
Outdoor connection disconnect-to-EVSE at EV-1..3 (firm rule equipment_disconnect_at_every_unit). (Model line id L-0029.) The model also raised 'connection method not detailed on E1.1', which the contract has no flag for; recorded here rather than dropped.
Counted 3 disconnect symbols tagged 'WP 60A/40ACLF 2P' on E1.1 enlarged plans 2 and 3 (1/4"=1'-0"), one at each EV charger EV-1/EV-2/EV-3, each with keynote 5 'PROVIDE WEATHERPROOF DISCONNECT SWITCH FOR EV CHARGER'. Sized from each unit's own callout; the E1.1 equipment schedule lists DISCONNECT SWITCH as type of connection for all three. Striking it removes the three EVSE disconnects. Step 4.5: EV-1..EV-3 are not listed in the equipment schedules read for this run (output/work/equipment holds only M0.2 AC-1/AC-2), so the switch could not be sized from a schedule MOCP; the line keeps the drawn 60A 2P fused / 40A CLF callout and a coverage gap names the units. (Model line id L-0043.) The model also raised 'unit-not-in-schedule', which the contract has no flag for; recorded here rather than dropped.
Three EVSE drawn on E1.1 enlarged plans 2 and 3 (1/4"=1'-0") (tags EV-1, EV-2, EV-3), listed in the E1.1 EQUIPMENT SCHEDULE as ChargePoint CT4011-GW1, 208V 1PH 30.0A 6240VA, connection DISCONNECT SWITCH. Hard-wired equipment (job-facts): each gets its J-box/connection even though no J-box symbol is drawn. Who furnishes the EVSE is not stated (E1.1 SN6 owner specs) -- carried as connection only. (Model line id L-0045.) The model also raised 'furnished_by_not_stated', which the contract has no flag for; recorded here rather than dropped.
Counted 3 drawn 1x4 suspended fixtures (legend symbol A, callout 'A (TYP)') on E4.0 1 ELECTRICAL LIGHTING PLAN, each tagged H-1a (panel H circuit 1, switch zone a - not a fixture type). Agrees with T-24 NRCC-LTI Table F count of 3. EC-furnished per SN2/GN24 (procure after architect/owner approval). Striking the line drops the sales-floor lighting. (Model line id L-0078.)
E1.1 SN1: rigid PVC coated on all elbows terminated to bottom of switchboard; one elbow each end of the 60 ft feeder. (Model line id L-0005.)
terminations_per_breaker: 200A 3P at MSB and 200A main in H. (Model line id L-0008.)
E3.0 SN5 flexible liquidtight metal conduit between disconnect and unit; E1.0 GN6 24" min weatherproof flex at mechanical equipment; 1 per AC-1/AC-2. (Model line id L-0028.)
Counted 2 thermostat symbols ('T' in circle with 'J' beside) on E3.0 plan 1: north wall (keynote 2) and east wall '(TYP)2'. Keynote 2 'PROVIDE JUNCTION BOX FOR THERMOSTAT'. No conduit or circuit drawn to them (thermostat wiring by mechanical). Striking it removes 2 boxes. (Model line id L-0060.)
Counted 2 ceiling receptacle symbols (circle with bar) tagged H-15 on E3.0 plan 1 -- one along the north storefront, one on the east storefront '(TYP)13'. Keynote 13 'PROVIDE CEILING MOUNTED RECEPTACLE FOR SHOW WINDOW'. Panel H ckt 15 RECEPTACLE-SHOW WINDOW. TR per GN23. Symbol named from reference (E1.0 legend), confirm duplex vs single. (Model line id L-0061.)
Counted 2 receptacle symbols tagged 'H-11 GFCI,WP' on E3.0 plan 2 (roof), one at each AC unit, keynote 6 (TYP) 'PROVIDE WEATHERPROOF AND GFCI PROTECTED RECEPTACLES WITHIN 25 FT OF HVAC EQUIPMENT'. GFCI carried at the device, WP in-use outdoors. Striking it removes 2 GFCI receptacles. (Model line id L-0063.)
2 AC units drawn on E3.0 roof plan with equipment schedule rows AC-1/AC-2 (208V 3ph 46.0A, disconnect switch). One termination each. Striking it removes both unit connections. (Model line id L-0068.)
Counted 2 recessed soffit squares (legend symbol B, 'B (TYP)') at the W entrance (H-5b) and NE corner entrance (H-5d) on E4.0. Agrees with T-24 NRCC-LTO count of 2. Outdoor lighting on photocontrol/astronomical time switch via LCP (SN8). (Model line id L-0079.)
Counted 2 wall sconce symbols (legend symbol C, callout '8 C (TYP)') tagged H-5c on the W and S exterior walls of E4.0. Agrees with T-24 NRCC-LTO count of 2. Keynote 8: photocontrol/astronomical time switch control. Mounted per E6.0 detail 8 (conduit feed or MC into concrete-wall box). (Model line id L-0080.)
Counted 2 boxed switch symbols marked '3' with zone letter a (fixture A zone) at the W entrance and NE entrance on E4.0, keynotes 3 and 4: SN4 'provide dimming control switch to suit light fixture's dimming requirement ... compatible dimming control switch & associated components'. Read as a 3-way 0-10V dimming control pair. (Model line id L-0085.)
E5.0 keynote 7 'PROVIDE AN ARC-FLASH HAZARD WARNING LABEL/SIGN IN ACCORDANCE TO CEC 2022 ART 110.16', tagged on the MSB; carried for MSB and panel H (the two pieces of gear on the single-line). (Model line id L-0109.)
E5.0 keynote 2 'PROVIDE NEW LAMINATED PANELBOARD'S NAMEPLATE' (tagged at panel H); carried for panel H and MSB. (Model line id L-0110.)
terminations_per_breaker: 800A 3P main. (Model line id L-0009.) The model also raised 'utility secondary conductors/lugs per PG&E - verify scope', which the contract has no flag for; recorded here rather than dropped.
E5.0: MBJ #250 KCMIL BCU; EBJ #250 KCMIL. (Model line id L-0011.)
terminations_per_breaker off panel H schedule: AC-1. (Model line id L-0018.)
terminations_per_breaker off panel H schedule: AC-2. (Model line id L-0019.)
Read off E2.1 (Title 24 NRCC-LTI-E indoor lighting certificate of compliance, page 6 of 7), Section V 'Declaration of Required Certificates of Acceptance': 'NRCA-LTI-02-A - Must be submitted for occupancy sensors and automatic time switch controls', systems/spaces to be field verified: TENANT SPACE. The form states the '-A' forms must be completed through an Acceptance Test Technician Certification Provider (ATTCP). Carried as one acceptance test for the tenant-space lighting controls (time switch / LCP per E3.0-E4.0; occupancy sensors if the lighting plan draws any). E2.0 deferred this line to the sheet that lists the NRCA forms, which is this one, so it is not duplicated. The outdoor-lighting test NRCA-LTO-02-A is listed on the outdoor T-24 sheet and is not carried here. Striking it removes the indoor lighting-controls acceptance test (1 ea) from the takeoff. (Model line id L-0057.)
Counted 1 WP J-box symbol ('J' in circle, 'WP', homerun H-13) at the NE corner entrance on E3.0 plan 1 (3/16"=1'-0"), keynote 12 'PROVIDE WEATHERPROOF JUNCTION BOX AND 3/4"C WITH PULL WIRE FOR SIGNAGE'. Striking it removes the signage box. (Model line id L-0058.)
Signage is hard-wired (job-facts 'Hard-wired equipment'; panel H ckt 13 SIGNAGE 1200 VA). The connection is taken at the WP J-box drawn on E3.0 (keynote 12). Striking it removes the sign termination. (Model line id L-0059.)
Counted 1 double-duplex symbol (circle with two bars) tagged H-9 on the west wall at the TEL/DATA backboard (keynote 3), E3.0 plan 1. Panel H ckt 9 TEL/DATA BACKBOARD. Not GFCI: no GF tag or note names it. Striking it removes 1 quad. (Model line id L-0062.)
Sized in Step 4.5 from AC-1's own entry in the M0.2 AC UNITS SCHEDULE (Trane WHC102H3, 208-230/3/60, MCA 46, MOCP 60): the next standard switch at or above the 60A MOCP is 60A, 3-pole, NEMA 3R because the unit is on the roof. E3.0 draws this disconnect fused ('WP 60A/60ACLF 3P', keynote 5 'PROVIDE NEW DISCONNECT SWITCH FOR AC UNIT'), so it is fused with fuses at the 60A MOCP (fuses carried on L-0066). Panel H shows AC-1 on 30A 3P, below the 60A MOCP -- see coverage gap. Striking this line removes AC-1's disconnect. (Model line id L-0064.)
Sized in Step 4.5 from AC-2's own entry in the M0.2 AC UNITS SCHEDULE (Trane WHC102H3, 208-230/3/60, MCA 46, MOCP 60): the next standard switch at or above the 60A MOCP is 60A, 3-pole, NEMA 3R because the unit is on the roof. E3.0 draws this disconnect fused ('WP 60A/60ACLF 3P', keynote 5 'PROVIDE NEW DISCONNECT SWITCH FOR AC UNIT'), so it is fused with fuses at the 60A MOCP (fuses carried on L-0066). Panel H shows AC-2 on 50A 3P, below the 60A MOCP -- see coverage gap. Striking this line removes AC-2's disconnect. (Model line id L-0065.)
STRUCK IN STEP 4.5 (was 4 ft): duplicate across sheets of L-0028, which carries the same item. The same two 1" LFMC whips at AC-1/AC-2, once as 4 ft and once as 2 ea; kept as whips. Quantity set to 0 rather than deleted so the strike is visible; restoring this line would count the item twice. Original reading: Keynote 5 'PROVIDE FLEXIBLE LIQUIDTIGHT METAL CONDUIT BETWEEN DISCONNECT SWITCH AND TERMINATION POINT AT MECHANICAL UNIT' and E1.0 GN6 (24" min WP flex at mechanical connections): 2 units x 2 ft = 4 ft of 1" LFMC. Not drawn to length; 24" minimum used. (Model line id L-0067.) The model also raised 'struck-duplicate', which the contract has no flag for; recorded here rather than dropped.
Drawn '(N) TEL/DATA BACKBOARD (3)' on W wall, E3.0 plan 1; SN3 'PROVIDE FIRE TREATED BACKBOARD THE ENTIRE LENGTH OF WALL UP TO CEILING HEIGHT'. Length of wall not dimensioned; one backboard carried. (Model line id L-0076.)
Counted 1 wall-mounted linear symbol (legend symbol D, callout 'D') tagged H-1e in the rear room by the SW door on E4.0. Agrees with T-24 count of 1. (Model line id L-0081.)
One LCP drawn beside panel H with keynote 7 (coordinate exact location) on E4.0; SN8 outdoor lighting on photocontrol or astronomical time switch; T-24 auto time switch. This is the same LCP as E3.0 keynote 11 - carry once for the job. (Model line id L-0086.) The model also raised 'same LCP as E3.0 keynote 11 - dedupe', which the contract has no flag for; recorded here rather than dropped.
Read off E5.0 detail 1 SINGLE LINE DIAGRAM: '(N) MAIN SWITCHBOARD "MSB", 800A, 208Y/120V, 3PH, 4W, NEMA 3R, 65 KAIC, NEMA-3R' with an 800A 3P main (keynote 11: 100% rated) and bus feeding a 200A 3P breaker to panel H and four 'SPACE FOR FUTURE PANEL' positions. KAIC is approximate only per SN6 -- EC to confirm available fault current with PG&E. Striking this line removes the service switchboard. (Model line id L-0090.)
Drawn on the E5.0 single-line: 'MAIN COLD WATER PIPE' electrode with keynote 3 'GROUNDING ELECTRODE CONNECTION SHALL BE WITHIN FIVE FEET OF THE METALLIC WATER SERVICE INCOMING LINE.' (Model line id L-0105.)
Drawn on the E5.0 single-line: GEC to 'BLDG. STRUCTURAL METAL FRAMING'. Connection method not stated; exothermic assumed. (Model line id L-0106.)
Drawn on the E5.0 single-line: 'UFER GROUND' with keynote 8 'PROVIDE GROUNDING AND BONDING METHODS IN ACCORDANCE TO CEC 2022 250.70.' Requires coordination with the footing pour. (Model line id L-0107.)
E5.0 keynote 10 and general note 1: 'GROUND RESISTANCE SHALL BE 25 OHMS OR LESS MEASURED BY THREE-POINT METHOD.' One test of the service grounding electrode system. (Model line id L-0108.)
E5.0 keynote 1 'PROVIDE TYPE WRITTEN PANEL DIRECTORY AT COMPLETION OF PROJECT', tagged at panel H. (Model line id L-0111.)
E6.0 detail 3 OSHA/NEC PLACARD: engraved black-on-white placard 'AREA IN FRONT OF THIS ELECTRICAL PANEL MUST BE KEPT CLEAR FOR 36 INCHES - OSHA-NEC REGULATIONS', pop-riveted in 2 places. Its note installs it 'at selected areas where shown on drawings and where possibility of blocking is anticipated as in storage rooms'. Carried as one at panel H (tenant space, W wall by rear door, beside the TEL/DATA backboard); MSB is outdoor. A plan callout on E3.0 would settle the count; striking the line removes one placard. (Model line id L-0113.) The model also raised 'verify_quantity', which the contract has no flag for; recorded here rather than dropped.
Counted 1 square tagged 'JUNCTION BOX' on Detail 10 VACUUM EQUIPMENT (1/4"=1'-0"), SD3 page 9 plan view, at the NW corner of the 8'-0" raised concrete pad, next to the recycling bin and the '(E) RELOCATED VACUUM EQUIPMENT'. Drawn 9 pt square = 6"x6" at 18 pt/ft. No E sheet shows the vacuum or this box (E1.0-E7.0 text has no 'VAC'), so it is taken here. Box is outdoors on a pad, so taken as weatherproof and stubbed up through the pad. Striking it removes the one pad box. (Model line id L-0114.) The model also raised "not on E sheets -- architect's site detail only", 'circuit/feeder not shown anywhere; see coverage_gaps', which the contract has no flag for; recorded here rather than dropped.
Counted 1 '(E) RELOCATED VACUUM EQUIPMENT' (plan circle and A-Elevation) on Detail 10 VACUUM EQUIPMENT (1/4"=1'-0"), SD3 page 9, served by the junction box of L-0001. The detail gives no voltage or load; connection taken as one equipment hookup at the new pad. Only the new-location reconnection is taken -- nothing for removing it from its old place. Striking it removes the one hookup. (Model line id L-0115.) The model also raised 'voltage/load unknown -- get vacuum nameplate', which the contract has no flag for; recorded here rather than dropped.
Added in Step 4.5 note-to-line audit: the Title 24 exterior compliance forms (E2.2/E2.3, summarised in job-facts) declare NRCA-LTO-02-A for the outdoor lighting controls (photocontrol + astronomical time switch at the LCP, E4.0 SN8), and only the indoor NRCA-LTI-02-A test (L-0057) had a line. One acceptance test for the exterior lighting controls. Confirm the form on E2.2/E2.3; striking this removes the outdoor acceptance test. (Model line id L-0117.) The model also raised 'added-step-4.5', 'confirm-sheet', which the contract has no flag for; recorded here rather than dropped.
Added by kelchlin from a suggestion: RRE priced this on 4 of 4 past jobs (100%). RRE carried these items at identical quantities on each of its last three jobs -- a fixed allowance, not a count (11.5 hr, $582). Recommended: RRE-HOUSE-KIT, once per job.
Added by kelchlin from a suggestion: RRE priced this on 3 of 4 past jobs (75%). RRE carried these at exactly these quantities on its two larger jobs (22.0 hr, $150), and about an eighth of them, with no backboard, on its smallest. Recommended: RRE-HOUSE-KIT-LOOSE on a job of restaurant or larger-retail size; leave it off a small fit-out.
NEC 2023 625.40, 625.54 EV charging: individual circuit and GFCI | to check | Each outlet for EV charging on an individual branch circuit, receptacles for EV charging GFCI protected, and EVSE over 60 A or 150 V to ground with a lockable disconnect. | 11 of 15 in play are not shown with it: #6 THWN CU; #6 AWG CU THWN (EVSE FEEDERS EV-1, EV-2); #10 THWN CU (GREEN, EQUIPMENT GROUND); and 8 more. | — |
NEC 2023 210.8(B), 406.9(B) GFCI, weather-resistant, in-use cover outdoors and on the roof | shown | Rooftop and outdoor receptacles GFCI protected, weather-resistant type, with an extra-duty in-use cover in wet locations. | In play for #12 THWN CU WIRE, ROOF; 3/4" RIGID GALVANIZED STEEL CONDUIT (RGS), ROOF; GFCI RECEPTACLE 20A 125V WEATHERPROOF, TR/WR, WITH IN-USE COVER (ROOF). Shown: #12 THWN CU WIRE, ROOF; 3/4" RIGID GALVANIZED STEEL CONDUIT (RGS), ROOF; GFCI RECEPTACLE 20A 125V WEATHERPROOF, TR/WR, WITH IN-USE COVER (ROOF). | RRE carries roof and patio receptacles as WR GFCI with an in-use cover where they are drawn (The Melt: 3). |
NEC 2023 210.62 Receptacles in show windows | shown | At least one 125-volt receptacle within 18 in. of the top of a show window for each 12 linear ft of show window. | In play for 3/4" EMT CONDUIT; DUPLEX RECEPTACLE 20A 125V TAMPER-RESISTANT, CEILING MOUNTED (SHOW WINDOW). Shown: 3/4" EMT CONDUIT; DUPLEX RECEPTACLE 20A 125V TAMPER-RESISTANT, CEILING MOUNTED (SHOW WINDOW). | — |
NEC 2023 210.63(B) Receptacle at indoor service equipment | shown | A 125-volt, 15- or 20-ampere receptacle within 50 ft of indoor electrical service equipment (other than one- and two-family dwellings). | In play for MAIN SWITCHBOARD MSB 800A 208Y/120V 3PH 4W NEMA 3R 65 KAIC, 800A 3P 100% RATED MAIN, (1) 200A 3P DISTRIBUTION BREAKER, (4) SPACES FOR FUTURE PANEL. Shown: GFCI RECEPTACLE 20A 125V WEATHERPROOF, TR/WR, WITH IN-USE COVER (ROOF). | — |
NEC 2023 250.50, 250.24, 250.104 Grounding electrode system at a new service | shown | A new service bonds every grounding electrode present (building steel, concrete-encased electrode, water pipe, rods) into one system, with a grounding electrode conductor to the service, and bonds the metal water and gas piping. | In play for MAIN SWITCHBOARD MSB 800A 208Y/120V 3PH 4W NEMA 3R 65 KAIC, 800A 3P 100% RATED MAIN, (1) 200A 3P DISTRIBUTION BREAKER, (4) SPACES FOR FUTURE PANEL. Shown: MAIN BONDING JUMPER #250 KCMIL CU; GROUNDING ELECTRODE CONNECTION, MAIN COLD WATER PIPE (#3/0 CU, LISTED CLAMP); GROUNDING ELECTRODE CONNECTION, BUILDING STRUCTURAL STEEL (#3/0 CU, EXOTHERMIC); and 2 more. | — |
NEC 2023 600.5(A) Sign outlet at each tenant entrance | shown | At least one outlet at each entrance to each tenant space accessible to pedestrians, for a sign, on a 20-ampere branch circuit that supplies no other load. | Shown: 3/4" EMT CONDUIT; JUNCTION BOX, WEATHERPROOF, CAST (WP J-BOX) FOR SIGNAGE, 3/4"C WITH PULL WIRE; EQUIPMENT CONNECTION, SIGNAGE 120V 1P (HARD-WIRED AT WP J-BOX). | RRE prices "power to building signage" where the set shows it; the matrix row is left blank where it does not. |
NEC 2023 600.6 Disconnect within sight of a sign | shown | Each sign or outline lighting system, or its feeder, has an externally operable disconnect within sight of the sign, or one capable of being locked in the open position. | In play for 3/4" EMT CONDUIT; JUNCTION BOX, WEATHERPROOF, CAST (WP J-BOX) FOR SIGNAGE, 3/4"C WITH PULL WIRE; EQUIPMENT CONNECTION, SIGNAGE 120V 1P (HARD-WIRED AT WP J-BOX). Shown: 1" PVC SCHEDULE 40 CONDUIT, UNDERGROUND; 1" LIQUIDTIGHT FLEXIBLE METAL CONDUIT WHIP WITH CONNECTORS (EVSE CONNECTION); DISCONNECT SWITCH 60A 2P 240V FUSED, NEMA 3R WEATHERPROOF (40A CLF), EV CHARGER; and 4 more. | RRE prices a WP switch at signage as a fused disconnect assembly (firm practice wp_switch_mapping). |
A takeoff cannot settle every article: load calculations and coordination are the engineer of record’s, and workmanship is the inspector’s. Each is listed so nothing is silently skipped. “Waiting on a code read” means the article is in play and this job’s drawing read has not been checked against the code yet: re-run the read, or check it on the drawings.
| 90 | Introduction | general | Scope and definitions: nothing to check on a job. |
| 100 | Definitions | general | Scope and definitions: nothing to check on a job. |
| 110 | Requirements for Electrical Installations | to check | 1 section checked against the takeoff, 1 to check: 110.24. |
| 200 | Use and Identification of Grounded Conductors | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 210 | Branch Circuits | checked | 3 sections checked against the takeoff, all shown. |
| 215 | Feeders | checked | In play; none of its checked sections applies to these lines. |
| 220 | Branch-Circuit, Feeder, and Service Load Calculations | design | The engineer of record’s: sizing, calculation or coordination, not checked against a takeoff. |
| 225 | Outside Branch Circuits and Feeders | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 230 | Services | checked | In play; none of its checked sections applies to these lines. |
| 235 | Branch Circuits, Feeders, and Services Over 1000 Volts ac, 1500 Volts dc | not in play | Nothing on this takeoff puts it in play. |
| 240 | Overcurrent Protection | checked | In play; none of its checked sections applies to these lines. |
| 242 | Overvoltage Protection | not in play | Nothing on this takeoff puts it in play. |
| 245 | Overcurrent Protection for Systems Rated Over 1000 Volts ac, 1500 Volts dc | not in play | Nothing on this takeoff puts it in play. |
| 250 | Grounding and Bonding | to check | 2 sections checked against the takeoff, 1 to check: 250.94. |
| 300 | General Requirements for Wiring Methods and Materials | to check | 1 section checked against the takeoff, 1 to check: 300.11, 410.36(B). |
| 305 | General Requirements for Wiring Methods and Materials for Systems Rated Over 1000 Volts ac, 1500 Volts dc | not in play | Nothing on this takeoff puts it in play. |
| 310 | Conductors for General Wiring | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 312 | Cabinets, Cutout Boxes, and Meter Socket Enclosures | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 314 | Outlet, Device, Pull, and Junction Boxes; Conduit Bodies; Fittings; and Handhole Enclosures | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 315 | Medium Voltage Conductors, Cable, Cable Joints, and Cable Terminations | not in play | Nothing on this takeoff puts it in play. |
| 320 | Armored Cable: Type AC | not in play | Nothing on this takeoff puts it in play. |
| 322 | Flat Cable Assemblies: Type FC | not in play | Nothing on this takeoff puts it in play. |
| 324 | Flat Conductor Cable: Type FCC |
| 400 | Flexible Cords and Flexible Cables | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 402 | Fixture Wires | not in play | Nothing on this takeoff puts it in play. |
| 404 | Switches | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 406 | Receptacles, Cord Connectors, and Attachment Plugs (Caps) | checked | In play; none of its checked sections applies to these lines. |
| 408 | Switchboards, Switchgear, and Panelboards | checked | In play; none of its checked sections applies to these lines. |
| 409 | Industrial Control Panels | not in play | Nothing on this takeoff puts it in play. |
| 410 | Luminaires, Lampholders, and Lamps | checked | In play; none of its checked sections applies to these lines. |
| 411 | Low-Voltage Lighting | not in play | Nothing on this takeoff puts it in play. |
| 422 | Appliances | checked | In play; none of its checked sections applies to these lines. |
| 424 | Fixed Electric Space-Heating Equipment |
| 500 | Hazardous (Classified) Locations, Classes I, II, and III, Divisions 1 and 2 | not in play | Nothing on this takeoff puts it in play. |
| 501 | Class I Hazardous (Classified) Locations | not in play | Nothing on this takeoff puts it in play. |
| 502 | Class II Hazardous (Classified) Locations | not in play | Nothing on this takeoff puts it in play. |
| 503 | Class III Hazardous (Classified) Locations | not in play | Nothing on this takeoff puts it in play. |
| 504 | Intrinsically Safe Systems | not in play | Nothing on this takeoff puts it in play. |
| 505 | Zone 0, 1, and 2 Locations | not in play | Nothing on this takeoff puts it in play. |
| 506 | Zone 20, 21, and 22 Locations for Combustible Dusts or Ignitible Fibers/Flyings | not in play | Nothing on this takeoff puts it in play. |
| 510 | Hazardous (Classified) Locations — Specific | not in play | Nothing on this takeoff puts it in play. |
| 511 | Commercial Garages, Repair and Storage | not in play | Nothing on this takeoff puts it in play. |
| 513 | Aircraft Hangars | not in play |
| 600 | Electric Signs and Outline Lighting | checked | 2 sections checked against the takeoff, all shown. |
| 604 | Manufactured Wiring Systems | not in play | Nothing on this takeoff puts it in play. |
| 605 | Office Furnishings | not in play | Nothing on this takeoff puts it in play. |
| 610 | Cranes and Hoists | not in play | Nothing on this takeoff puts it in play. |
| 620 | Elevators, Dumbwaiters, Escalators, Moving Walks, Platform Lifts, and Stairway Chairlifts | not in play | Nothing on this takeoff puts it in play. |
| 625 | Electric Vehicle Power Transfer System | to check | 1 section checked against the takeoff, 1 to check: 625.40, 625.54. |
| 626 | Electrified Truck Parking Spaces | not in play | Nothing on this takeoff puts it in play. |
| 630 | Electric Welders | not in play | Nothing on this takeoff puts it in play. |
| 640 | Audio Signal Processing, Amplification, and Reproduction Equipment | not in play | Nothing on this takeoff puts it in play. |
| 645 | Information Technology Equipment | not in play |
| 700 | Emergency Systems | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 701 | Legally Required Standby Systems | not in play | Nothing on this takeoff puts it in play. |
| 702 | Optional Standby Systems | not in play | Nothing on this takeoff puts it in play. |
| 705 | Interconnected Electric Power Production Sources | not in play | Nothing on this takeoff puts it in play. |
| 706 | Energy Storage Systems | not in play | Nothing on this takeoff puts it in play. |
| 708 | Critical Operations Power Systems (COPS) | not in play | Nothing on this takeoff puts it in play. |
| 710 | Stand-Alone Systems | not in play | Nothing on this takeoff puts it in play. |
| 712 | Direct Current Microgrids | not in play | Nothing on this takeoff puts it in play. |
| 722 | Cables for Power-Limited Circuits and Fault-Managed Power Circuits | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 724 | Class 1 Power-Limited Circuits and Class 1 Power-Limited Remote-Control and Signaling Circuits |
| 800 | General Requirements for Communications Systems | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 805 | Communications Circuits | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 810 | Radio and Television Antenna Equipment | not in play | Nothing on this takeoff puts it in play. |
| 820 | Community Antenna Television and Radio Distribution Systems | not in play | Nothing on this takeoff puts it in play. |
| 830 | Network-Powered Broadband Communications Systems | not in play | Nothing on this takeoff puts it in play. |
| 840 | Premises-Powered Broadband Communications Systems | not in play | Nothing on this takeoff puts it in play. |
| Ch. 9 | Tables: conduit fill, conductor properties, power-limited sources | checked | In play; none of its checked sections applies to these lines. |
| RRE’s part |
|---|
| Sheet |
|---|
WIRE, 0-10V DIMMING CONTROL PAIR 2 #16 (CLASS 1 RATED) - IN LIGHTING EMT Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E4.0 |
1" RIGID GALVANIZED STEEL CONDUIT (RGS), ROOF Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E3.0 |
#3/0 AWG BARE CU GROUNDING ELECTRODE CONDUCTOR (GEC) Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E5.0 |
5" PVC SCHEDULE 40 CONDUIT, UNDERGROUND (PG&E SECONDARY) Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E1.1 |
1" RIGID STEEL CONDUIT, PVC-COATED, EXPOSED EXTERIOR Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E1.1 |
CIRCUIT BREAKER 20A 1P BOLT-ON (PANEL H) Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E5.0 |
FUSE 40A 250V CURRENT-LIMITING (CLASS RK1/J), DUAL ELEMENT Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E1.1 |
FUSE 60A 250V CLASS RK5 DUAL-ELEMENT CURRENT-LIMITING Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E3.0 |
CIRCUIT BREAKER 40A 2P BOLT-ON (PANEL H, EV-1/EV-2/EV-3 EVSE) Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E5.0 |
CIRCUIT BREAKER 200A 3P IN MSB (SERVES PANEL H) Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E5.0 |
PANELBOARD H 120/208V 3PH 4W 225A BUS, 200A 3P MAIN BREAKER, 42 CKT, BOLT-ON, SURFACE, 22 KAIC Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E5.0 |
CIRCUIT BREAKER 30A 3P BOLT-ON (PANEL H, AC-1) Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E5.0 |
CIRCUIT BREAKER 50A 3P BOLT-ON (PANEL H, AC-2) Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E5.0 |
CIRCUIT BREAKER 200A 3P IN MSB (FEEDS PANEL H) Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E5.0 |
PANELBOARD 225A BUS 200A 3P MAIN BREAKER 120/208V 3PH 4W 42 CKT BOLT-ON SURFACE 22KAIC Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E5.0 |
CIRCUIT BREAKER 20A 1P 120V BOLT-ON Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E5.0 |
CIRCUIT BREAKER 30A 3P 208V BOLT-ON Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E5.0 |
CIRCUIT BREAKER 50A 3P 208V BOLT-ON Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E5.0 |
CIRCUIT BREAKER 40A 2P 208V BOLT-ON Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E5.0 |
FUSE 60A 250V CURRENT-LIMITING CLASS RK5 Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E3.0 |
FUSE 40A 250V CURRENT-LIMITING CLASS RK5 Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E1.1 |
1" PVC SCH 40 CONDUIT UNDERGROUND - EV-1 FEEDER Struck by kelchlin: Not in this job (struck on drawing E5.0). | — | not stated | Struck: not in this bid | E5.0 |
1" PVC SCH 40 CONDUIT UNDERGROUND - EV-2 FEEDER Struck by kelchlin: Not in this job (struck on drawing E5.0). | — | not stated | Struck: not in this bid | E5.0 |
1" PVC SCH 40 CONDUIT UNDERGROUND - EV-3 FEEDER Struck by kelchlin: Not in this job (struck on drawing E5.0). | — | not stated | Struck: not in this bid | E5.0 |
2" PVC SCH 40 CONDUIT (FEEDER MSB TO PANEL H) Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E5.0 |
#6 AWG CU THWN EQUIPMENT GROUND (FEEDER MSB TO PANEL H) Struck by kelchlin: Not in this job (struck on drawing E5.0). | — | not stated | Struck: not in this bid | E5.0 |
1" PVC SCH 40 CONDUIT (EVSE FEEDERS) Struck by kelchlin: Not in this bid: answered on the drawing instead of a RRE Components item. | — | not stated | Struck: not in this bid | E5.0 |
#10 AWG CU THWN EQUIPMENT GROUND (EVSE FEEDERS) Struck by kelchlin: Not in this job (struck on drawing E5.0). | — | not stated | Struck: not in this bid | E5.0 |
| Nothing on this takeoff puts it in play. |
| 326 | Integrated Gas Spacer Cable: Type IGS | not in play | Nothing on this takeoff puts it in play. |
| 330 | Metal-Clad Cable: Type MC | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 332 | Mineral-Insulated, Metal-Sheathed Cable: Type MI | not in play | Nothing on this takeoff puts it in play. |
| 334 | Nonmetallic-Sheathed Cable: Types NM and NMC | not in play | Nothing on this takeoff puts it in play. |
| 335 | Instrumentation Tray Cable: Type ITC | not in play | Nothing on this takeoff puts it in play. |
| 336 | Power and Control Tray Cable: Type TC | not in play | Nothing on this takeoff puts it in play. |
| 337 | Type P Cable | not in play | Nothing on this takeoff puts it in play. |
| 338 | Service-Entrance Cable: Types SE and USE | not in play | Nothing on this takeoff puts it in play. |
| 340 | Underground Feeder and Branch-Circuit Cable: Type UF | not in play | Nothing on this takeoff puts it in play. |
| 342 | Intermediate Metal Conduit: Type IMC | not in play | Nothing on this takeoff puts it in play. |
| 344 | Rigid Metal Conduit: Type RMC | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 348 | Flexible Metal Conduit: Type FMC | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 350 | Liquidtight Flexible Metal Conduit: Type LFMC | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 352 | Rigid Polyvinyl Chloride Conduit: Type PVC | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 353 | High Density Polyethylene Conduit: Type HDPE Conduit | not in play | Nothing on this takeoff puts it in play. |
| 354 | Nonmetallic Underground Conduit with Conductors: Type NUCC | not in play | Nothing on this takeoff puts it in play. |
| 355 | Reinforced Thermosetting Resin Conduit: Type RTRC | not in play | Nothing on this takeoff puts it in play. |
| 356 | Liquidtight Flexible Nonmetallic Conduit: Type LFNC | not in play | Nothing on this takeoff puts it in play. |
| 358 | Electrical Metallic Tubing: Type EMT | checked | In play; none of its checked sections applies to these lines. |
| 360 | Flexible Metallic Tubing: Type FMT | not in play | Nothing on this takeoff puts it in play. |
| 362 | Electrical Nonmetallic Tubing: Type ENT | not in play | Nothing on this takeoff puts it in play. |
| 366 | Auxiliary Gutters | not in play | Nothing on this takeoff puts it in play. |
| 368 | Busways | not in play | Nothing on this takeoff puts it in play. |
| 369 | Insulated Bus Pipe (IBP)/Tubular Covered Conductors (TCC) Systems | not in play | Nothing on this takeoff puts it in play. |
| 370 | Cablebus | not in play | Nothing on this takeoff puts it in play. |
| 371 | Flexible Bus Systems | not in play | Nothing on this takeoff puts it in play. |
| 372 | Cellular Concrete Floor Raceways | not in play | Nothing on this takeoff puts it in play. |
| 374 | Cellular Metal Floor Raceways | not in play | Nothing on this takeoff puts it in play. |
| 376 | Metal Wireways | not in play | Nothing on this takeoff puts it in play. |
| 378 | Nonmetallic Wireways | not in play | Nothing on this takeoff puts it in play. |
| 380 | Multioutlet Assembly | not in play | Nothing on this takeoff puts it in play. |
| 382 | Nonmetallic Extensions | not in play | Nothing on this takeoff puts it in play. |
| 384 | Strut-Type Channel Raceway | not in play | Nothing on this takeoff puts it in play. |
| 386 | Surface Metal Raceways | not in play | Nothing on this takeoff puts it in play. |
| 388 | Surface Nonmetallic Raceways | not in play | Nothing on this takeoff puts it in play. |
| 390 | Underfloor Raceways | not in play | Nothing on this takeoff puts it in play. |
| 392 | Cable Trays | not in play | Nothing on this takeoff puts it in play. |
| 393 | Low-Voltage Suspended Ceiling Power Distribution Systems | not in play | Nothing on this takeoff puts it in play. |
| 394 | Concealed Knob-and-Tube Wiring | not in play | Nothing on this takeoff puts it in play. |
| 395 | Outdoor Overhead Conductors over 1000 Volts | not in play | Nothing on this takeoff puts it in play. |
| 396 | Messenger-Supported Wiring | not in play | Nothing on this takeoff puts it in play. |
| 398 | Open Wiring on Insulators | not in play | Nothing on this takeoff puts it in play. |
| not in play |
| Nothing on this takeoff puts it in play. |
| 425 | Fixed Resistance and Electrode Industrial Process Heating Equipment | not in play | Nothing on this takeoff puts it in play. |
| 426 | Fixed Outdoor Electric Deicing and Snow-Melting Equipment | not in play | Nothing on this takeoff puts it in play. |
| 427 | Fixed Electric Heating Equipment for Pipelines and Vessels | not in play | Nothing on this takeoff puts it in play. |
| 430 | Motors, Motor Circuits, and Controllers | not in play | Nothing on this takeoff puts it in play. |
| 440 | Air-Conditioning and Refrigerating Equipment | checked | In play; none of its checked sections applies to these lines. |
| 445 | Generators | not in play | Nothing on this takeoff puts it in play. |
| 450 | Transformers and Transformer Vaults (Including Secondary Ties) | not in play | Nothing on this takeoff puts it in play. |
| 455 | Phase Converters | not in play | Nothing on this takeoff puts it in play. |
| 460 | Capacitors | not in play | Nothing on this takeoff puts it in play. |
| 470 | Resistors and Reactors | not in play | Nothing on this takeoff puts it in play. |
| 480 | Stationary Standby Batteries | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 490 | Equipment Over 1000 Volts, Nominal | not in play | Nothing on this takeoff puts it in play. |
| Nothing on this takeoff puts it in play. |
| 514 | Motor Fuel Dispensing Facilities | not in play | Nothing on this takeoff puts it in play. |
| 515 | Bulk Storage Plants | not in play | Nothing on this takeoff puts it in play. |
| 516 | Spray Application, Dipping, Coating, and Printing Processes | not in play | Nothing on this takeoff puts it in play. |
| 517 | Health Care Facilities | not in play | Nothing on this takeoff puts it in play. |
| 518 | Assembly Occupancies | not in play | Nothing on this takeoff puts it in play. |
| 520 | Theaters, Audience Areas of Motion Picture and Television Studios, Performance Areas, and Similar Locations | not in play | Nothing on this takeoff puts it in play. |
| 522 | Control Systems for Permanent Amusement Attractions | not in play | Nothing on this takeoff puts it in play. |
| 525 | Carnivals, Circuses, Fairs, and Similar Events | not in play | Nothing on this takeoff puts it in play. |
| 530 | Motion Picture and Television Studios and Similar Locations | not in play | Nothing on this takeoff puts it in play. |
| 540 | Motion Picture Projection Rooms | not in play | Nothing on this takeoff puts it in play. |
| 545 | Manufactured Buildings and Relocatable Structures | not in play | Nothing on this takeoff puts it in play. |
| 547 | Agricultural Buildings | not in play | Nothing on this takeoff puts it in play. |
| 550 | Mobile Homes, Manufactured Homes, and Mobile Home Parks | not in play | Nothing on this takeoff puts it in play. |
| 551 | Recreational Vehicles and Recreational Vehicle Parks | not in play | Nothing on this takeoff puts it in play. |
| 552 | Park Trailers | not in play | Nothing on this takeoff puts it in play. |
| 555 | Marinas, Boatyards, Floating Buildings, and Commercial and Noncommercial Docking Facilities | not in play | Nothing on this takeoff puts it in play. |
| 590 | Temporary Installations | not in play | Nothing on this takeoff puts it in play. |
| Nothing on this takeoff puts it in play. |
| 646 | Modular Data Centers | not in play | Nothing on this takeoff puts it in play. |
| 647 | Sensitive Electronic Equipment | not in play | Nothing on this takeoff puts it in play. |
| 650 | Pipe Organs | not in play | Nothing on this takeoff puts it in play. |
| 660 | X-Ray Equipment | not in play | Nothing on this takeoff puts it in play. |
| 665 | Induction and Dielectric Heating Equipment | not in play | Nothing on this takeoff puts it in play. |
| 668 | Electrolytic Cells | not in play | Nothing on this takeoff puts it in play. |
| 669 | Electroplating | not in play | Nothing on this takeoff puts it in play. |
| 670 | Industrial Machinery | not in play | Nothing on this takeoff puts it in play. |
| 675 | Electrically Driven or Controlled Irrigation Machines | not in play | Nothing on this takeoff puts it in play. |
| 680 | Swimming Pools, Fountains, and Similar Installations | not in play | Nothing on this takeoff puts it in play. |
| 682 | Natural and Artificially Made Bodies of Water | not in play | Nothing on this takeoff puts it in play. |
| 685 | Integrated Electrical Systems | not in play | Nothing on this takeoff puts it in play. |
| 690 | Solar Photovoltaic (PV) Systems | not in play | Nothing on this takeoff puts it in play. |
| 691 | Large-Scale Photovoltaic (PV) Electric Supply Stations | not in play | Nothing on this takeoff puts it in play. |
| 692 | Fuel Cell Systems | not in play | Nothing on this takeoff puts it in play. |
| 694 | Wind Electric Systems | not in play | Nothing on this takeoff puts it in play. |
| 695 | Fire Pumps | not in play | Nothing on this takeoff puts it in play. |
| not in play |
| Nothing on this takeoff puts it in play. |
| 725 | Class 1, Class 2, and Class 3 Remote-Control, Signaling, and Power-Limited Circuits | not read yet | In play. This job’s read has no code pass yet: re-run the read, or check it on the drawings. |
| 726 | Class 4 (CL4) Fault-Managed Power Systems | not in play | Nothing on this takeoff puts it in play. |
| 728 | Fire-Resistive Cable Systems | not in play | Nothing on this takeoff puts it in play. |
| 750 | Energy Management Systems | not in play | Nothing on this takeoff puts it in play. |
| 760 | Fire Alarm Systems | not in play | Nothing on this takeoff puts it in play. |
| 770 | Optical Fiber Cables | not in play | Nothing on this takeoff puts it in play. |